Free EMA Electrician Licence Written Assessment Practice Questions

100 free questions · Answer explanations · No signup required

View examination details, outline and sources

Loading selected examination banks…

Sample Practice Questions

Try these 10 sample questions from the EMA Electrician Licence Written Assessment practice bank. Each includes the answer and explanation. Continue with the interactive practice above to review the full question set.

  1. 1A domestic circuit supplies appliances through several socket outlets. Under regulation 2 of the Electricity (Electrical Installations) Regulations, which term describes this circuit?

    1. A.Distribution circuit
    2. B.Final circuitCorrect answer: B
    3. C.Control circuit
    4. D.Auxiliary circuit

    Explanation: Regulation 2 defines a final circuit as "a circuit connected either directly to a device which utilises electricity, or indirectly to such a device by means of one or more socket outlets or other outlet points". The appliance circuit meets the indirect socket-outlet branch of that definition.

    Reference: Electricity (Electrical Installations) Regulations — reg. 2, definition of final circuit

  2. 2A domestic single-line diagram needs a device designation that expressly identifies protection by residual-current detection. Which name specifically denotes that function?

    1. A.Miniature circuit breaker
    2. B.Moulded-case circuit breaker
    3. C.Residual current circuit breakerCorrect answer: C
    4. D.Thermal overload relay unit

    Explanation: The source states "The current balance in the conductors passing through the magnetic core therefore no longer exists, and the difference gives rise to a magnetic flux in the core.". An RCCB uses the residual-current principle. Overcurrent circuit breakers and thermal overload relays respond to different quantities unless additional residual-current functionality is specified. This asks what the designation expressly identifies, rather than whether an overcurrent breaker could have added residual-current accessories.

    Reference: Schneider Electric Electrical Installation Guide — Description of RCDs — Operating principle

  3. 3An electrician must state the voltage of an AC circuit using the meaning assigned by the Electricity (Electrical Workers) Regulations. Which characteristic of the waveform is the statutory AC voltage?

    1. A.The arithmetic mean over a complete cycle
    2. B.The maximum instantaneous peak value
    3. C.The difference between waveform extremes
    4. D.The root mean square over a complete cycleCorrect answer: D

    Explanation: Regulation 2 specifies "in the case of alternating current, the virtual voltage or root mean square value (or the square root of the mean or average value of the squares of the instantaneous values) of the voltage during the complete cycle." Thus RMS, rather than mean, peak or peak-to-peak voltage, is required.

    Reference: Electricity (Electrical Workers) Regulations — reg. 2, definition of voltage, paragraph (b)

  4. 4On a switchboard drawing, an MCB is specified with a thermal-magnetic trip unit. Which part responds to a sustained overload?

    1. A.The thermally operated bimetal stripCorrect answer: A
    2. B.The electromagnetic striker pin
    3. C.The manual operating handle
    4. D.The mechanical contact linkage

    Explanation: The source states "a thermally-operated bi-metal strip detects an overload condition, while an electromagnetic striker pin operates at current levels reached in short-circuit conditions". The thermal element responds to overload heating; the magnetic striker responds to short-circuit-level current. The handle and linkage operate the mechanism but do not provide overload sensing.

    Reference: Schneider Electric Electrical Installation Guide — Circuit-breaker construction — Description, trip-mechanism actuating device

  5. 5When classifying a proposed installation under the Electricity (Electrical Installations) Regulations, what are the respective maximum AC and DC voltages within the definition of extra-low voltage?

    1. A.50 V AC and 120 V DCCorrect answer: A
    2. B.50 V AC and 50 V DC
    3. C.120 V AC and 120 V DC
    4. D.120 V AC and 50 V DC

    Explanation: Regulation 2 states "a voltage not exceeding 50V a.c. or 120V d.c., whether between conductors or between conductor and Earth". These are inclusive upper limits; the other pairs interchange the AC and DC thresholds or use one threshold for both.

    Reference: Electricity (Electrical Installations) Regulations — reg. 2, definition of extra-low voltage

  6. 6An electrician reviews an RCD sensing-core arrangement on a single-phase circuit with separate L, N and PE conductors. Which conductors pass through the sensing core to compare outgoing and returning load current?

    1. A.The line and protective conductors
    2. B.The line and neutral conductorsCorrect answer: B
    3. C.The neutral and protective conductors
    4. D.The line, neutral and protective conductors

    Explanation: The guide states "A magnetic core encompasses all the current-carrying conductors of an electric circuit". Here those are L and N. PE remains outside the core so earth-fault return current creates an imbalance. Including PE could cancel that imbalance; omitting L or N prevents the intended normal-current comparison.

    Reference: Schneider Electric Electrical Installation Guide — Description of RCDs — Operating principle, current-carrying conductors and earth-fault return path

  7. 7A switching-device specification requires making and breaking normal current, and making, carrying briefly and breaking a specified short-circuit current. Which defined device meets that description in the Electricity (Electrical Installations) Regulations?

    1. A.Switch
    2. B.Disconnector
    3. C.Circuit breakerCorrect answer: C
    4. D.Contactor

    Explanation: The circuit-breaker definition includes "making and carrying for a limited time and breaking an electricity current under specified abnormal circuit conditions including a short circuit". Regulation 2 defines a switch as carrying abnormal current for a limited time, without that short-circuit breaking function. The specified combination is a circuit breaker.

    Reference: Electricity (Electrical Installations) Regulations — reg. 2, definition of circuit breaker, paragraph (b)

  8. 8An electrician prepares a single-line drawing for a new 30 kVA installation. What should this drawing principally show?

    1. A.The positions of fittings on the floor plan
    2. B.The internal terminal wiring of each appliance
    3. C.The mechanical dimensions of the switchboard
    4. D.The electrical circuits of the installationCorrect answer: D

    Explanation: The source states "Single-line drawing is the plan showing the electrical circuits of the electrical installation.". A single-line design drawing represents circuit connections. A location plan, appliance wiring diagram and mechanical panel drawing serve different purposes.

    Reference: EMA Handbook for Application of Electrical Installation Licence — p. 5, §6.2 footnote 7

  9. 9A worker is to be appointed as a competent person to carry out work on high voltage apparatus. Whose appointment gives the worker that status under regulation 2 of the Electricity (Electrical Installations) Regulations?

    1. A.The licensee responsible for the installation
    2. B.The authorised high voltage switching engineerCorrect answer: B
    3. C.The transmission licensee supplying the site
    4. D.The Authority licensing electrical workers

    Explanation: A competent person is "a person appointed by an authorised high voltage switching engineer to carry out work on a high voltage apparatus". The appointing role is therefore the authorised switching engineer, rather than the installation licensee, transmission licensee or Authority.

    Reference: Electricity (Electrical Installations) Regulations — reg. 2, definition of competent person

  10. 10Four identical motors each have a 10 kVA input rating. For this design, each motor's maximum utilisation factor is specified as 0.75 and the group's coincidence factor as 0.80. What maximum group demand should the electrician use?

    1. A.24 kVACorrect answer: A
    2. B.30 kVA
    3. C.32 kVA
    4. D.40 kVA

    Explanation: For utilisation the guide states "This factor must be applied to each individual load"; for coincidence it states "The factor ks is applied to each group of loads". Individual utilisation gives 4 × 10 kVA × 0.75 = 30 kVA; group coincidence gives 30 × 0.80 = 24 kVA. Omitting coincidence gives 30 kVA, omitting utilisation gives 32 kVA, and omitting both gives 40 kVA. The factors are supplied design assumptions, not universal Singapore values.

    Reference: Schneider Electric Electrical Installation Guide — Maximum kVA demand — Maximum utilisation and coincidence factors

Exam Review

About EMA Electrician Licence Written Assessment

EMA Electrician Licence Written Assessment · SG

Key exam facts

Provider
Energy Market Authority (EMA), Singapore, administers the Electrician Licence written assessment and assigns the available written-assessment slot through its ELISE licensing process.
Format
Written knowledge assessment comprising 60 multiple-choice questions in domestic installations, industrial installations and legislation, plus 4 structured questions on electrical drawings and designs. The later practical test and technical assessment interview are separate and excluded.
Exam questions
Total questions: 64.
Time limit
3 hours for the written test.
Passing score
At least 50% overall, provided that the candidate obtains at least 75% in Section E (Regulation). The five sections carry 240 marks in total.
Exam fee
S$50 non-refundable licence application fee. A separate S$30 licence fee is payable only after approval and passing the assessments. EMA does not identify a separate written-test fee in its published application-fee information.

Topics covered

  • Electricity Act and relevant Electricity Regulations (31.25%)

    • Definitions in the regulations
    • Authority conferred by license under different classes of Licensed Electrical Workers
    • Responsibility of holder of each class of licence
    • Connection of electrical installation to supply line
    • Modification to electrical installation / supply installation
    • Compliances on testing of electrical installation / supply installation
    • Person responsible for electrical installation / supply installation
  • Domestic and Industrial Installations (68.75%)

    • Understanding the design of single line diagram (SLD)
    • Purpose of each electrical symbol in the SLD. Able to identify the symbol conventions and functions used in the protective devices, such as MCB, RCCB… etc.
    • Typical arrangement of incoming protective devices, outgoing protective devices, external protection devices, measuring instruments, indicating lights…etc. in a circuit.
    • Able to design a SLD for small installation (up to 45kVA)
    • Design of an electrical installation
    • Able to calculate maximum demand based on domestic/industrial design requirements
    • Calculate protective devices’ rating
    • Calculation and selection of cable size
    • Application of correction factors for ambient temperature, grouping, insulation, harmonics etc.
    • Selection of wiring installation, enclosure, cable conduits, trunking, cable trays …etc.
    • Calculation of voltage drop in electrical circuits, maximum voltage drops allowance and acceptable limits, methods to reduce voltage drops
    • Segregation of different circuits due to voltage limits, types of loads, mutual interference
    • Protection against electric shock
    • Types of electrical shocks (direct contact, indirect contact)
    • Protective measures to prevent electric shock and its applications
    • Application of basic protection and fault protection
    • Physiological effect of electric current
    • Calculation of touch voltage
    • Sensitivity of RCCB (nuisance tripping etc.)
    • Earthing and bonding
    • Types of Earthing systems (TN-S, TT etc.)
    • Bonding in the protection against electric shock
    • Purpose of earthing
    • Purpose of bonding
    • Earthing and bonding connection methods
    • Identifying extraneous conductive parts
    • Alternating Current (AC) and Direct Current (DC) supplies
    • Voltage levels in Singapore
    • Application of ohm’s law, Kirchhoff’s laws, Thevenin’s theorem, electrical quantities in mean and r.m.s. value in circuits
    • relationship between three phase line current and phase current and relationship between three phase line voltage and phase voltage
    • Generation of Direct Current (DC) electricity, conversion of electricity from AC to DC, DC to AC, principles of solar PV, battery supply
    • harmonics due to non-linear loads
    • colour code identification for single phase AC, three phase AC and DC cables
    • power factor in electrical circuits, power factor correction methods, problems due to low power factors
    • Principles of operation of rotating machines, AC and DC machines
    • Characteristics of motor starting methods (direct-on-line, star-delta, soft starter)
    • Control diagram of motor control circuits, interlocking, start-stop control, emergency stop, sequential starting, use of PLC, relays and contactors
    • trouble shooting of machines, abnormal humming sound, machines stalled, machines cannot be started
    • Able to calculate real, apparent and reactive power of a motor
    • Principles and operation of small generator
    • Generator protection
    • Generator installation
    • Pre-commissioning and turn-on inspection & test
    • Types of the commissioning tests and the purpose of each test
    • Visual Inspection
    • Earth resistance test
    • Insulation resistance test
    • Phasing and polarity test
    • Continuity test
    • Earth loop impedance test
    • RCCB test
    • MCCB trip test
    • Voltage measurement
    • Use of common test instruments
    • Operation, testing and maintenance of small electrical installation
    • Tests after supply turn-on
    • Electrical safety requirements for temporary electrical installation, SOA

How to prepare

Work through the topics, read the explanation after each answer, and revisit the areas where you miss questions. Use the official outline and reference materials below to guide your study.

These independent practice questions are not actual exam items and do not guarantee a passing result.

Frequently asked questions

What is the exam format?

Written knowledge assessment comprising 60 multiple-choice questions in domestic installations, industrial installations and legislation, plus 4 structured questions on electrical drawings and designs. The later practical test and technical assessment interview are separate and excluded.

How many questions are on the exam?

Total questions: 64.

How long is the exam?

3 hours for the written test.

What is the passing score?

At least 50% overall, provided that the candidate obtains at least 75% in Section E (Regulation). The five sections carry 240 marks in total.

How much does the exam cost?

S$50 non-refundable licence application fee. A separate S$30 licence fee is payable only after approval and passing the assessments. EMA does not identify a separate written-test fee in its published application-fee information.

Official sources and references

Confirm current exam arrangements with the exam provider.