Try these 10 sample questions from the BICSI Outside Plant Designer (OSP) practice bank. Each includes the answer and explanation. Continue with the interactive practice above to review the full question set.

  1. 1A proposed outside plant technology must support a specified service capacity. What evidence best supports accepting the technology during pre-design research?

    1. A. A list of projects that purchased equipment from the same vendor
    2. B. Standards-based technical information showing how the design provides the required capacity
    3. C. A comparison of enclosure sizes without the associated transmission specifications
    4. D. The manufacturer's product release date and expected delivery schedule

    Answer: B

    Explanation: The guide states, "You must include appropriate standards-based information concerning the proposed technology." Technical capability evidence addresses the service requirement. Purchasing history, packaging, and availability do not establish the capacity that the proposed network will provide.

    Reference: Rural Telecommunications Infrastructure Loan Program Application Guide — Section 3.3.1, Description of Proposed Technology, p.16

  2. 2Records do not resolve whether undisclosed subsurface structures occupy a proposed vault excavation. Which assessment directly investigates that uncertainty?

    1. A. Measure visible surface features and project them downward
    2. B. Use an adjacent vault excavation as proof of identical conditions
    3. C. Check design clearances against the same unverified records
    4. D. Make test holes within the proposed excavation area

    Answer: D

    Explanation: RUS states, "test holes may be required to verify that construction can be carried out as planned to avoid useless excavation." Local test holes directly investigate the uncertain subsurface conditions. Surface projection, extrapolation from a neighboring excavation, and rechecking unresolved records do not establish conditions at this location.

    Reference: Underground Plant Design — RUS Bulletin 1751F-643 — Section 10.1, p.24

  3. 3Which transmission medium provides immunity to electromagnetic interference in the signal-carrying medium?

    1. A. Unshielded copper twisted pair
    2. B. Shielded copper twisted pair
    3. C. Glass optical fiber
    4. D. Copper coaxial cable

    Answer: C

    Explanation: Eaton identifies "immunity to electromagnetic interference (EMI)" as a fiber benefit. Glass carries the optical signal without the electrical pickup mechanism of metallic transmission conductors. Copper shielding can reduce interference but does not turn the conductor into an EMI-immune optical medium.

    Reference: Fiber Optic Cable Buying Guide — How fiber optic cables work

  4. 4An underground conduit system must accommodate expected cable additions with fewer future street excavations. Which design provision directly supports that objective?

    1. A. Provide exactly the initial occupied ducts, with capacity recorded on the plans
    2. B. Provide larger access vaults, with the initial duct count between each vault
    3. C. Install spare conduits continuously along the anticipated expansion route
    4. D. Provide spare duct stubs at vaults, with no spare ducts between the vaults

    Answer: C

    Explanation: RUS recommends "more conduits than initially needed" to avoid reopening trenches for additional conduits. Continuous spare conduits provide the future pathway. Documentation alone adds no physical capacity, and larger vaults or isolated spare stubs still leave the inter-vault route requiring new excavation.

    Reference: Underground Plant Design — RUS Bulletin 1751F-643 — Section 2.11, p.11

  5. 5During trench excavation for a buried cable, the work approaches the estimated location of an existing utility. What additional location determination is required by OSHA?

    1. A. Use the approximate surface mark as the exact vertical location
    2. B. Determine the exact utility location by safe and acceptable means
    3. C. Proceed at the planned depth because the utility has already been marked
    4. D. Wait until the utility is contacted to confirm its location

    Answer: B

    Explanation: OSHA states that when work approaches the estimated position, "the exact location of the installations shall be determined by safe and acceptable means." An estimated mark does not establish the exact position. Continuing on an assumption or waiting for contact defeats the required verification.

    Reference: 1926.651 — Specific Excavation Requirements — 29 CFR 1926.651(b)(3)

  6. 6Before personnel or equipment are supported on an existing pole structure during telecommunications field work, what must be established?

    1. A. Competent inspection verifies strength, condition, and secure support
    2. B. An installation-age record substitutes for inspection of present condition
    3. C. A visual check of the upper pole substitutes for assessing the full support
    4. D. The original load rating substitutes for checking damage and deterioration

    Answer: A

    Explanation: OSHA requires the structure to be "first inspected by a competent person" and found adequately strong, in good working condition, and secured. Age or original rating does not establish its current condition. Inspecting only the upper part leaves the remainder of the actual support unassessed.

    Reference: 1910.268 — Telecommunications — 29 CFR 1910.268(b)(6)

  7. 7What should a preliminary outside plant design summary explain when several feasible network plans were considered?

    1. A. Describe the selected plan and retain alternative analysis outside the design record
    2. B. List each alternative's cost and leave the selection rationale unstated
    3. C. Discuss the alternatives and explain why the recommended plan was selected
    4. D. Describe rejected plans without relating their limitations to the selected plan

    Answer: C

    Explanation: The guide requires "a discussion of any alternate plans considered and reasons for the selection of the recommended plan." The summary needs both the alternatives and the selection rationale. Keeping alternatives elsewhere, listing costs without reasons, or discussing rejections without explaining the recommendation leaves that required design reasoning incomplete.

    Reference: Rural Telecommunications Infrastructure Loan Program Application Guide — Section 3.3.1, Proposed System—Design Summary and Analysis, p.17

  8. 8Which instrument does the RUS splicing standard specify for end-to-end optical cable acceptance tests?

    1. A. A visual fault locator
    2. B. A connector inspection microscope
    3. C. An optical power meter
    4. D. An optical time-domain reflectometer

    Answer: C

    Explanation: The standard states, "5.6.6 An optical power meter shall be used for end-to-end cable acceptance tests." Section 5.6.5 separately specifies OTDR use for splice and signature tests. A visual fault locator and a connector inspection microscope do not measure the required end-to-end transmitted optical power.

    Reference: RUS Standard for Splicing Copper and Fiber Optic Cables — Bulletin 1753F-401 — Printed p.18 — Equipment Requirements — optical power meter for end-to-end cable acceptance tests

  9. 9Before award of an RUS outside plant construction contract, what is the purpose of the pre-bid conference?

    1. A. Rank submitted bids to identify the lowest responsive construction offer
    2. B. Negotiate a binding individual contract price with the preferred bidder
    3. C. Explain project scope and special considerations and clarify bidder concerns
    4. D. Approve each bidder's financial and technical qualifications for contract award

    Answer: C

    Explanation: The regulation states that the pre-bid conference is to "acquaint the bidders with the scope and special considerations of the project and to clarify any concerns the bidders may have." Its function is common project understanding. Bid evaluation, individual price negotiation, and award qualification decisions are different procurement functions.

    Reference: 7 CFR Part 1753 — Telecommunications System Construction Policies and Procedures — 7 CFR 1753.48(a)(3)(ii)

  10. 10Which outside plant platform places cables in ducts connected by underground access vaults?

    1. A. Direct-buried cable plant
    2. B. Messenger-supported aerial plant
    3. C. Underground conduit plant
    4. D. Self-supporting aerial plant

    Answer: C

    Explanation: RUS states, "Underground plant consists of a conduit and an underground cable vault (UCV) system". This platform carries cables through the duct-and-vault pathway. Direct burial places cable directly in soil; the two aerial alternatives support it above ground rather than in this underground pathway.

    Reference: Underground Plant Design — RUS Bulletin 1751F-643 — Section 1.2, p.7

Topics in this practice bank

These topics describe the available practice for BICSI Outside Plant Designer (OSP). Review the examination outline and its sources for scope and allocation details.

  • Pre-Design Preparation
    • Research types and capabilities of existing technology
    • Research existing infrastructure/information-gathering
    • Research geography
    • Determine financial parameters
    • Comply with local, state, and national regulations
    • Assess program/client requirements and forecast for the future
    • Interpret customer’s IT and facility master plan
  • Perform Site Survey
    • Perform pre-job assessment for new and existing construction
    • Perform additional pre-job assessment for existing construction
    • Determine easements and requirements for right of way
    • Determine proposed routing
    • Verify network topology
  • Select Media, Platform, and Cables
    • Select appropriate media
    • Select copper AWG and sizing
    • Select fiber mode and type
    • Select coaxial
    • Select splicing hardware
    • Select termination hardware
    • Select splitters
    • Select alternative media
  • Design Underground Platform and Spaces
    • Design underground support structure-conduit
    • Design underground support structure-maintenance hole
    • Design underground support structure-hand hole/pull box
    • Design underground support structure-contained environmental vault
    • Design underground grounding systems
    • Design utility tunnel pathways
    • Design transition structures
  • Design Buried Platform and Spaces
    • Design buried application-trench
    • Design buried application-plowed
    • Design buried application-bore
    • Design buried grounding systems
  • Design Aerial Platform and Spaces
    • Design aerial support structure-existing
    • Design aerial support structure-new construction
    • Design aerial support structure-messenger
    • Design aerial support structure-anchors and guys
    • Design aerial structure grounding-multiground neutral distribution system
    • Design aerial structure grounding based on delta systems
    • Design aerial structure grounding based on wye systems
    • Design aerial structure grounding-special situations
    • Determine space allocation on pole
    • Select cable attachment method and associated hardware
    • Design aerial-to-underground transition structures
    • Design optical ground wire structures
    • Design all dielectric self-supporting (ADSS) support structures
  • Prepare Design
    • Prepare preliminary design
    • Prepare critical design review scope/design development
    • Prepare final design (construction) package
    • Prepare rough order magnitude (ROM)
  • Quality Control Process
    • Develop quality control process
    • Implement design change process
    • Identify common mistakes
    • Design betterments/optimization
  • Professional Responsibilities
    • Perform pre-award responsibilities
    • Perform post-award responsibilities