1A laboratory's quality control result falls outside its prescribed range. What conclusion follows for the associated patient results?
- A. The patient results remain verified because the controls were tested.
- B. The patient results cannot yet be considered reliably accurate.
- C. The patient results are accurate if their values look clinically plausible.
- D. The patient results become reliable after a proficiency test is submitted.
Answer: B
Explanation: CMS states, "If the QC results are not within the prescribed range or the expected pattern, then the laboratory cannot be sure that the patients test results are accurate and reliable." Therefore an out-of-range control prevents assurance about those patient results.
Reference: Good Laboratory Practices for Waived Testing — page 3, item 14
2In a conventional absorption spectrophotometer, which component selects a narrow wavelength range?
- A. Monochromator
- B. Sample holder
- C. Photodetector
- D. Readout display
Answer: A
Explanation: The UC Davis manual states that the instrument uses "a monochromator (usually a reflection grating with associated optics) to select a narrow range of wavelengths." Detector and display have other roles.
Reference: UC Davis Chemistry Laboratory Manual: Quantitative Spectrophotometry — Operation of Spectrometer
3Which leukocyte is the most common and serves as a major immediate defense against infection?
- A. Neutrophil
- B. Eosinophil
- C. Basophil
- D. Monocyte
4Why is INR calculated from a prothrombin time result?
- A. To improve comparison among laboratories and methods
- B. To correct PT for a patient's platelet count
- C. To remove all anticoagulant effects from PT
- D. To convert PT directly into a factor concentration
Answer: A
Explanation: NLM says PT results vary by lab or method and that INR "makes it easier for health care providers to compare and better understand results from different labs or test methods." This is standardization of PT interpretation.
Reference: Prothrombin Time Test and INR (PT/INR) — What is a prothrombin time test with an INR (PT/INR)?
5Which immunoglobulin class is usually produced first after exposure to a germ?
6In forward ABO grouping, what is mixed with the patient's red cells?
- A. Anti-A and anti-B reagents
- B. Known A and B red cells
- C. Patient platelets and serum
- D. Donor plasma and saline
7Under the FDA-approved SOLX System labeling, at what temperature are CPD/AS-7 leukocyte-reduced red cells stored?
- A. 1 to 6°C
- B. 20 to 24°C
- C. −18°C or colder
- D. 10 to 15°C
8What bacterial property is the basis of the Gram stain's positive-versus-negative differential reaction?
- A. Chemical and physical properties of the cell wall
- B. Rate of bacterial division in broth
- C. Ability to produce catalase bubbles
- D. Amount of extracellular capsule produced
Answer: A
Explanation: The CDC job aid describes Gram staining as a procedure that categorizes bacteria "based on the chemical and physical properties of their cell walls." Growth rate, catalase, and capsule quantity do not define this stain reaction.
Reference: Gram Stain | CDC OneLab REACH — Introduction, page 1
9Which nephron structure initially filters small molecules, wastes, and water from the blood?
- A. Glomerulus
- B. Proximal convoluted tubule
- C. Loop of Henle
- D. Distal convoluted tubule
10What is the primary role of a control material with a known analyte value in patient testing?
- A. To assign a diagnostic reference interval for each patient.
- B. To replace a patient's specimen when volume is insufficient.
- C. To check whether the test system is functioning as expected.
- D. To calculate the laboratory's annual testing volume.
Answer: C
Explanation: CMS explains that controls are "materials with known values of the substance measured that help the laboratory achieve accurate and reliable testing by checking if the test system is working." A known-value control tests system performance.
Reference: Good Laboratory Practices for Waived Testing — page 2, item 13
Topics in this practice bank
These topics describe the available practice for AMT examination for MLS. Review the examination outline and its sources for scope and allocation details.
General Laboratory
- Laboratory quality
- Laboratory laws and regulations
- Laboratory safety
- Laboratory instrumentation, maintenance, and principles of operation
- Laboratory mathematics
- General microscopy
- Biological specimen collection and processing
- Phlebotomy and specimen collection, handling, and integrity
- Patient identification
- Waived testing
Chemistry
- Instrumentation
- Renal function tests
- Hepatic function tests
- Carbohydrate metabolism
- Protein analysis
- Enzymology
- Endocrinology
- Lipids
- Water and electrolytes
- Acid-base balance
- Cerebrospinal fluid (CSF)
- Other chemistry procedures
Hematology
- General knowledge
- Erythrocyte procedures
- Cytogenic and molecular assays
- Automated instrumentation
- Coagulation and Hemostasis
Immunology and Serology
- General knowledge
- Serological tests
- Analytic procedures
- Special procedures
Immunohematology
- Blood typing
- Immune response
- Compatibility testing principles and procedures
- Rh immune globulin
- Special tests
- Blood Banking and Transfusion Services
Microbiology
- Bacteriology: general knowledge
- Bacteriology: media quality control, techniques, and cultures
- Bacteriology: bacterial identification
- Virology
- Parasitology
- Mycology
Urinalysis and Body Fluids
- Renal function
- Urinalysis procedures
- Special tests
How to use these free practice questions
Choose an answer, check the explanation, and review your progress by chapter. Practice questions and explanations are free to access without signing up.
These are independent study questions, not actual examination items. For examination requirements and official information, view AMT examination for MLS details.