OpenExamsFREE PRACTICE — ANY EXAM

New Mexico Contractor Business & Law — Requirements & Free Practice

US-NM · License preparation

99 free questions · Answer explanations · No signup required

Choose what to practice

Start with an exam below. Your examination requirements depend on your application pathway. View licensing requirements

Combined practice

Choose an exam or combined practice to begin.

Licenses, application pathways and examination requirements

Each license and applicant pathway has its own requirements and exemptions. Choosing practice questions does not determine your eligibility.

Contractor’s License

Business-entity license authorizing contracting only in its approved classifications; general, specialty, electrical and mechanical classifications are applicant scope conditions.

Licensing authority: New Mexico Regulation and Licensing Department, Construction Industries Division · Application information

Addition or replacement of an existing qualifying party or classification
No examination is required for this applicant pathway.
Application
Submit the signed/notarized status-change form with fees; use an already valid certificate within its reattachment period.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Qualifying Party
Employ or be owned by a CID-certified qualifying party in every requested classification. This route uses an already issued, eligible certificate rather than first-issuance examination scores.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.

Official no-examination sources

Effective from 2026-09-22.

Addition of a new qualifying party/classification — EE 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EE-98 — (a) EE-98. Residential, and commercial and industrial electrical wiring 5000 volts, nominal or less. Requires four years’ experience. Includes all electrical systems and wiring methods operating at 5000 volts, nominal, or less; electrical systems and wiring methods identified in electrical specialty classifications ES-1, ES-2, ES-3 and ES-7 ES-10R, or ES-10 residential electrical systems and wiring methods identified in classification ER-1; trenching and ductwork associated with classification EL-1; associated excavating, trenching, boring, shoring, backfilling, compacting for all electrical systems and wiring methods of 5000 volts, nominal or less. Does not include electrical wiring defined in the EL-1 classification other than trenching and duct work as specified above.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the electrical NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in EE-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — EL 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EL-1 — (c) EL-1. Electrical distribution and transmission systems over 5000 volts, nominal. Requires four years’ experience. Includes all electrical systems and wiring methods operating at over 5000 volts, nominal; overhead or underground electrical distribution and transmission circuits, equipment,; associated towers, tower foundations and other supporting structures; associated excavating, trenching, boring, shoring, backfilling, compacting and ductwork; sub-stations and terminal facilities. Does not include any electrical wiring specified or other electrical classifications EE-98, ER-1, ES-1, ES-2, ES-3, ES-7, ES-10R or ES-10. (2) Electrical Specialty licenses.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in EL-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ER 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ER-1 — (b) ER-1. Residential electrical wiring 5000 volts, nominal or less. Requires two years’ experience. Includes electrical systems and wiring methods of 5000 volts, nominal or less at residential one and two-family dwelling units; multi-family dwellings when all such units are all on the ground floor with no occupancies above or below, as set forth in 14.10.4 NMAC. Does not include wiring for commercial use, such as motels, hotels and similar occupancies. May not contract for more than four dwelling units in any single building or structure.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ER-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ES 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-1 — (a) ES-1. Electrical signs and outline lighting. Requires two years’ experience. Installation at commercial locations only. Outline lighting is an arrangement of LED, incandescent lamps, or gaseous tubes to outline and call attention to certain features such as the shape of a building or the decoration of a window and may or may not contribute to the general illumination of an area. Includes commercial electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the sign or outline lighting where a “sign circuit” or outline lighting circuit has been provided within 10 feet of the roof or wall of the structure supporting the sign or outline lighting; concrete for the foundation of poles; build structures for the support of such signs associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the “sign circuit” not to exceed 10 feet from the foundation of the sign. 14.6.6 NMAC 6
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ES 10

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10 — (f) ES-10. Water well pump installer. Requires two years’ experience. Commercial water well pumps, 600 volts or less, single or three phase. Includes the installation, maintenance, repairing or replacing electrical equipment, wiring, and accessories directly associated with water well pump systems; variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation and trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment. Does not include systems over 600 volts, electrical services, building wiring or any other electrical wiring.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-10 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ES 10R

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10R — (e) ES-10R. Residential water well pump installer. Requires two years’ experience. Residential water well pumps, 120/240 volts or less, single phase 15 HP or less. Includes the installation, maintenance, repairing or replacement of electrical equipment, wiring, and accessories directly associated with water well pump systems; single phase variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation, trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment; does not include electrical systems over 240 volts, pumps over 15 HP, electrical services, building wiring or any other electrical wiring.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-10R and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ES 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-2 — (b) ES-2. Cathodic protection and lightening protection systems. Requires two years’ experience. Includes interior and exterior cathodic protection and lightening protection systems at commercial and residential locations; electrical wiring methods of 5000 volts, nominal or less required to complete a cathodic grounding protection system only; electrical wiring methods of 5000 volts, nominal or less required to complete a lightening protection system only. May not install the service riser, main service or service grounding.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ES 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-3 — (c) ES-3. Low voltage special systems (under 50 volts). Requires two years’ experience. Interior and exterior special systems, cabling and interconnections at commercial and residential locations, privately and publically owned operating at 50 volts or less; includes telecommunications systems; fire alarm systems, CATV systems; audio and visual systems; security systems; door and gate operated control circuits; temperature control circuits, other low voltage specialty systems operating at 50 volts or less; low voltage special systems cables installed in plenum or non-plenum rated walls or ceilings; low voltage special systems cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial low voltage special systems cables; overhead low voltage special systems cabling to structures; terminations and splicing of low voltage special system conductors; associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods required to complete any of the special systems listed above. An installer of television receive-only (TVROs) (dishes) is not required to have a contractor’s license when the installation is in a single-family dwelling and does not require the use of 120 volts for tracking. Does not include interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 or ER-1 classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — ES 7

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-7 — (d) ES-7. Telephone communication systems. Requires two years’ experience. Interior and exterior telecommunications cabling and interconnections at commercial and residential locations, in publicly or privately owned buildings; includes telecommunication cables installed in plenum or non-plenum rated walls or ceilings; telecommunication cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial telecommunication cables; overhead telecommunication cabling to structures; terminations and splicing of communication conductors; associated excavating trenching, boring, shoring, backfilling, compacting, installation of underground electrical wiring methods required to complete the installation of telecommunications systems; terminal facilities; installation of integrated services digital network cross connect equipment; installation of VoIP switching technology equipment, repeaters, including the installation of instruments at their terminating locations. Does not include Interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-7 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GA 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-1 — (1) GA-1. Streets, roads and highways, including tunnels, parking lots, alleys, seal coat and surfacing. Requires two years’ experience. Clear, align, fill, compress, compact, build up or remove earth and do all work necessary to prepare, within the assigned rights-of-way, the land to accept a streets, roads, highways including culverts and tunnels, and alleys; includes parking lots, sidewalks or driveways; place and finish concrete or bituminous materials and apply sealcoat. This classification includes the scopes of work authorized by GA-2 and GA-3.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GA 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-2 — (2) GA-2. Maintenance and repair. Requires two years’ experience. Fix, maintain, repair, patch, mend, cover, fill or replace with materials of like substances to that currently existing on streets, roads, highways, parking lots, driveways, sidewalks and alleys; apply seal coat to driveways and parking lots. Install rumble strips.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GA 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-3 — (3) GA-3. Curbs, gutters and driveway culverts. Requires two years’ experience. Form, place and finish concrete curbs, gutters, driveway culverts, public sidewalks and bituminous ridge curbs for the deflection of water.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GA 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-4 — (4) GA-4. Striping. Requires two years’ experience. Paint directional stripes on paved roads, streets, highways, alleys and parking lots; install auto parking bumpers or stops and highway lane markers/reflectors.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GA 5

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-5 — (5) GA-5. Highway signs and guard rails. Requires two years’ experience. Erect and stabilize signs and guard rails along public highways, streets, roads and alleys, which are used for the direction and safety of vehicular traffic. Electrical signs must be installed by a properly licensed electrical contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-5 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GA 98
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-98 — (6) GA-98. Asphalt, bitumen and concrete construction. Indicates licensure in classifications GA-1 through GA-5; and covers all work authorized in those classifications. B. Residential and commercial building.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
Four years under the May 2025 QP application for GA-98
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GB 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-2 — (1) GB-2. Residential. Requires two years’ of foreman level practical or related trade experience. Erect, alter, repair or demolish residences and apartment houses accommodating not more than four family units, Groups R-1, R-2 and R-3, as those groups are defined in 14.7.2 NMAC; items included in Group U, as defined in 14.7.2 NMAC, when incidental to these structures; includes all work described by the GS specialty classifications, provided the work is limited to residential construction as defined under this provision.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GB-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GB 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-98 — (2) GB-98. General building. Requires four years of foreman level practical or related trade experience of which at two years must be commercial experience. Erect, alter, repair or demolish residential and commercial buildings, and certain structures; includes all work authorized by the GB-2, GF-5, GF-7 and GS classifications; seal coating and striping of driveways and parking lots; excludes those structures covered by the EE, MM, GA or GF classifications. C. Fixed works. Construct, alter or repair fixed or public works facilities; provided, however, that work in any trade or craft that is authorized by any one, or a combination of, the mechanical, electrical, or general building or LP Gas classifications must be performed by an entity validly licensed in the appropriate classification. Except as may be expressly provided in a specific classification description, fixed works licensees may not construct buildings that are primarily for the use and occupancy of the general public, but may bid and contract for such buildings when they are incidental to a fixed works project; however, such work must be subcontracted pursuant to Subsection B of 14.6.6.8 NMAC, above. Incidental storage buildings used exclusively for storage and not for occupancy are allowed within these classifications. 14.6.6 NMAC 2
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
Four years of foreman-level practical or related trade experience, including two years of commercial experience.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the general construction NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GB-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-1 — (1) GF-1. Airports. Requires two years’ experience. Construct, alter and repair airports, including excavating, grading, compacting, sub-surfacing, surfacing (dirt or bitumen and concrete), marking and other work on surfaces to be used for aircraft traffic, landing, take-off and taxi.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-2 — (2) GF-2. Bridges. Requires two years’ experience. Erect, construct, alter, repair or demolish any bridge, overpass or underpass, culvert or ramp, generally used for vehicular traffic.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-3 — (3) GF-3. Canals, reservoirs, dams and irrigation systems. Requires two years’ experience. Construct, erect, alter, repair, or demolish canals, dams, reservoirs irrigation systems; excavate, ditch, fill, compact and place pre-cast components, waterproof membranes and liners, concrete reinforcement, abutments and buttresses in connection therewith; install tanks, pumps, pipelines and substations incidental to the project; irrigation activities and piping when applicable solely to the production of agriculture or maintenance of livestock on a farm or ranch, excluding electrical work, are exempt from licensing requirements.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-4 — (4) GF-4. Drainage or flood control systems. Requires two years’ experience. Construct, erect, install, repair and alter drainage or flood control systems; dig, excavate, fill, prepare embankments for such purposes, place pre-cast components, concrete reinforcement and perform all other work incidental to these projects.; install storm sewers, including trenching, boring, shoring, backfilling, compacting, and paving.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 5

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-5 — (5) GF-5. Recreation areas. Requires two years’ experience. Construct, prepare, clear, repair or alter facilities for use as recreation areas, including but not limited to golf courses, driving ranges, water parks, tennis courts, playgrounds, outdoor athletic facilities, miniature golf courses, pitch-and-putt golf courses; prepare the area by excavation, fill, including foundations, retaining walls, sprinkler systems, rest benches, shade and rain shelters and foot bridges relative to recreation areas; public campgrounds and parks or similar facilities, including toilet facilities and lean-tos.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-5 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 6

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-6 — (6) GF-6. Railroad and tunnel construction. Requires two years’ experience. Construct railroad lines, including clearing, filling, shaping, compacting, placing rip-rap, stabilizing, setting roadbeds, ties, tie plates, rails, rail connectors, frogs, switch plates, switches, and all appurtenances necessary for an operational railroad line, including bridges, culverts, tunnels, retaining walls, dikes, gates, tool sheds and landing or parking platforms for equipment. Includes welding operations necessary for rail construction.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-6 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 7

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-7 — (7) GF-7. Tanks and towers. Requires two years’ experience. Construct or fabricate on site and install tanks for the storage of solids or liquids, above or below ground, and towers such as radio, television and telecommunications towers, including all necessary site-work, excavation and construction of concrete tanks, pads and foundations, cutting, welding, placement of structural members, engineered structural support systems for elevated tanks, and engineered or prefabricated towers; includes the repair and placement of liners in tanks, and incidental storage buildings.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-7 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 8

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-8 — (8) GF-8. Transmission lines, tanks and substations (non-electrical). Requires two years’ experience. Build, construct and place lines for the transmission or conveyance of natural gas or petroleum, water and other fluid substances, including the application of protective coatings, trenching, boring, shoring, backfilling, compacting, paving and surfacing necessary and incidental to the completion of the installation of such facilities. Includes incidental buildings, tanks, and substations required for the project; construct, alter or repair industrial plants, including, but not limited to, refineries and power generation plants.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-8 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 9

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-9 — (9) GF-9. Utility lines and systems (sewage, water, natural gas and underground telephone cables). Requires two years’ experience. Construct, install, alter or repair utility lines and utility systems for the transmission of sewage, natural gas and water, including excavating, grading, trenching, boring, shoring, backfilling, compacting, paving and surfacing; includes tanks, pumps, lift-stations and substations incidental to the project; construct, alter, or repair treatment plants and facilities incidental thereto; install direct burial communications cable by trenching, direct plowing or pulling direct burial cable through existing raceways and install vaults as directed by the telecommunications utility; associated excavating, trenching, boring, shoring, backfilling, compacting, paving and surfacing. Shall not perform installation of electrical raceways including directional boring or pipe jacking methods, splicing, termination, installation of load pots, installation of integrated services digital network cross connect equipment, installation of VoIP switching technology equipment, overhead cabling work, or other activities considered under the scope of the ES-7, EL-1, ES-3 or EE-98 electrical classifications.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-9 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GF 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-98 — (10) GF-98. Construct, alter or repair fixed works facilities. Requires four years’ experience; indicates licensure in classifications GF-1 through GF-9 and authorizes all work described in these classifications. D. General Specialty classifications. General construction includes numerous specialties. Therefore, CID has established the GS classification series to enable entities that perform this kind of work to be 14.6.6 NMAC 3
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 1
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-1 — (1) GS-1. Acoustical insulation and insulation. Requires two years’ experience. Install any insulating material, including urethane foam and approved waterproof membranes and coatings, in or on buildings, structures and on piping for the purpose of energy conservation, temperature and sound control, and fireproofing. Does not include the installation of urethane roof systems.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 13

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-13 — (8) GS-13. Framing. Requires two years of foreman level practical or related trade experience; cut, join, install wood, metal or other products approved by the division and utilized for the framing of a structure or building, including bearing and non-bearing walls, rafters, headers, trusses, joists, studs, door and window rough frames, and roof decks, including repair to any of the above.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-13 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 14
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-14 — (9) GS-14. Windows, doors and skylights. Requires two years’ experience. Fabricate and install windows and doors in buildings and structures, including the necessary installation of window, door and skylight framing, and the installation of necessary hardware; cut, assemble and install glass work, and execute the glazing of frames, panels, sash and doors; fabricate and install storm doors, windows, and skylights including flashing; does not include structural alterations to enlarge any opening.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-14 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Vendor Door Exam
The April 2026 PSI bulletin names GS-6 Door Installation, whereas the March 2022 codified classification is GS-14 Windows, doors and skylights. Neither source explicitly assigns the GS-6 paper to GS-14; that association is undetermined and is not inferred from topic overlap.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 15
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-15 — (10) GS-15. Caissons, piers and pile driving. Requires two years’ experience. Install piers, caissons and pilings through the use of pile driving equipment and machinery, including necessary excavation, grading and clearing for site preparation for pile driving activities; cut, weld, join and fabricate caissons or piles; install all necessary concrete and reinforcing steel within the caissons to create a structural member; soil stabilization and rock-fall mitigation.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-15 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 16

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-16 — (11) GS-16. Masonry. Requires two years’ experience. Install or erect brick and other baked clay products, rough cut and dressed stone, artificial stone and pre-cast blocks, structural glass brick or block adobe, laid at random or in courses, with or without mortar, to form masonry walls, anchored stone or masonry veneer, including building walls, freestanding walls six feet or higher from ground level and retaining walls measuring thirty-six inches or more measured from the bottom of the footing; does not include the execution, fabrication and erecting of poured cement and concrete, except as a foundation for a wall. 14.6.6 NMAC 4
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-16 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 2
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-2 — (2) GS-2. Awnings and canopies. Requires two years’ experience. Construct, erect and install awnings and canopies, attached to buildings and structures or free standing, including, but not limited to carports and service station canopies, and including necessary excavation and foundation work. All electrical work shall be performed by a properly licensed electrical contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 21

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-21 — (12) GS-21. Roofing. Requires two years of foreman level practical or related trade experience. Install, alter or repair roof systems on new or existing roof decks to create a weatherproof and waterproof protective membrane, with or without insulation, using asphalt, pitch, tar, sealants, felt, shakes, shingles, roof tile, slate, urethane or any other approved materials including the preparatory work necessary to bring a roof deck or an existing roof to a condition where roofing can be installed, and sealed or repaired; includes cutting, shaping, fabricating, and installing of sheet metal such as cornices, flashing, skylights (excluding alterations to structural framing), roof coatings, gutters, leaders, rainwater downspouts, pans, prefabricated chimneys, at or near roof lines, metal flues, or doing any part of any combination thereof, which relate to and are incidental to roofing projects.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-21 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 23
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-23 — (13) GS-23. Sign construction (non-electrical). Requires two years’ experience. Fabricate on site, install and erect signs of wood, steel, plastic or any material, or any combination of materials, which are to be embedded in the earth, in concrete or other base material, or attached to buildings or structures using anchors, attached cables, bars or similar devices and appurtenances; electrified signs shall only be installed by contractors holding an ES-1 or an EE-98 classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-23 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 24

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-24 — (14) GS-24. Structural steel erection. Requires two years of foreman level practical or related trade experience. Fabricate on site and erect structural steel shapes and plates, of any profile, perimeter or cross-section that may be used as structural members for buildings and structures, including riveting and welding; does not authorize construction of concrete foundations or complete buildings.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-24 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 25

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-25 — (15) GS-25. Swimming pools (non-plumbing, mechanical or electrical). Requires two years’ experience. Construct and repair swimming pools including excavation, installation of reinforcing steel or mesh, application of concrete and special coatings; shall not perform any scope of work which is authorized by a plumbing, mechanical, electrical or LP Gas classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-25 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 29
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-29 — (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
up to four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-29 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 30

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-30 — (16) GS-30. Plastering, stucco and lathing. Requires two years’ experience. Prepare wall and ceiling surfaces, interior or exterior, with wood, metal lath, wallboard or other properly prepared surfaces which will accept and hold a mixture of sand, plaster (including gypsum plaster), lime and water, or sand and cement with water or any combination of materials to create a permanent surface coating; these coatings may be applied manually or mechanically on surfaces which will support such coating; install steel or wood or other division approved stud systems (non-structural), channel iron work and affix lath or any other materials or products, prepared or manufactured to provide a base for such coatings.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-30 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 31
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-31 — (17) GS-31. Siding. Requires two years’ experience. Apply, replace, or repair siding consisting of slate, gypsum, wood, plastics or other products, including the application of furred up networks on which the siding can be installed.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-31 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 32
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-32 — (18) GS-32. Miscellaneous sheet metal. Requires two years’ experience. Fabricate on site and install sheet metal (galvanized iron) such as cornices, flashing, gutters, leaders, rainwater downspouts, pans, and prefabricated chimneys; shall not install heating, ventilation & air conditioning (HVAC) duct systems, vents, grease hoods, or other appurtenances that are authorized by mechanical or plumbing classifications.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-32 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 34
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-34 — (19) GS-34. Concrete coring, drilling and slab sawing. Requires two years’ experience. Coring, boring, drilling, cutting, and sawing concrete, including the removal or demolition of the material; does not include the installation of electrical wiring or plumbing in such bored, drilled, cut or sawed concrete. (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis. [14.6.6.9 NMAC - Rp, 14.6.6.9 NMAC, 3/10/2022]
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-34 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-4 — (3) GS-4. Concrete, cement, walkways and driveways. Requires two years’ experience practical trade experience, one year of which must be foreman level. Mix, pour, place, and finish concrete,; includes all necessary preparatory work including excavation, form work, and placing of reinforcement materials; includes the installation on private property of curbs, gutters, sidewalks, and driveway culverts; may not perform this work in public rights-of-way unless subcontracted to a validly licensed GA licensee.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
Two years of practical trade experience, including one year at foreman level.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 5
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-5 — (4) GS-5. Demolition. Requires two years’ experience. Demolish all or any portion of a buildings and structures authorized by the GB-98 classification, including demolition to portions of buildings and structures allowing additions and alterations to be completed to the remaining portions of the building or structure.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-5 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 7

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-7 — (5) GS-7. Drywall installation and texture. Requires two years’ experience. Installation of gypsum wallboard, and gypsum sheathing; includes taping, bedding and coating the surfaces of the wallboard and sheathing with gypsum joint systems, tape and drywall mud, or a combination of other materials to create a permanent surface or coating and of walls and ceilings; install steel or wood stud systems (non-structural) and channel iron work to provide a base for the application of drywall.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-7 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 8

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-8 — (6) GS-8. Earthmoving, excavating and ditching. Requires two years’ experience. Perform earthwork associated with or incidental to construction projects regulated by CID, using hand or power tools, machines that use air, fluids, or other material under pressure, or heavy equipment, in such a manner that cutting, filling, excavating, grading, trenching, backfilling, boring and any similar excavating activity can be executed; earthmoving, excavating and ditching activities applicable to the preparation and production of agriculture or maintenance of livestock on a farm or ranch are exempt from licensing requirements.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-8 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — GS 9

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-9 — (7) GS-9. Elevators, escalators, and related machinery (non-electrical). Requires two years’ experience. Erect, install or repair elevators, escalators and related machinery, including sheave beams, sheaves, cable and wire rope, guides, cab, counterweights, doors, including sidewalk elevators, automatic and manual controls, signal systems and all other devices, apparatus, machinery and equipment (including fabrication on job site) essential to the safe and efficient installation and operation of electrical, hydraulic and manually operated elevators and escalators and conveyors designed specifically for the transportation of people.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-9 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MM 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-1 — (1) MM-1. Plumbing. Requires four years’ experience. Install, alter, repair, service, and maintain plumbing, plumbing fixtures, and piping, includes incidental concrete supports, and excavating, trenching and backfilling; includes hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; piping for fuel, oil and gasoline; piping and appurtenances for solar thermal energy systems; potable water irrigation sprinkler systems; swimming pools and spas; includes pneumatic or electric controls and control wiring not greater than 24 volts; septic tanks, manholes and sewer lines; does not include installation of natural gas fired appliances or natural gas piping; piping and agricultural sprinkler irrigation system installation and maintenance on farm or ranch property that moves water for livestock use or irrigation purposes from a privately owned well or pipeline, not connected to a public potable water supply are exempt from licensing requirements. When connected to a potable water source all connections must be downstream of an approved back flow prevention device. If a backflow prevention device is required it shall be permitted and installed by a properly certified journeyman employed by an appropriately licensed contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MM 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-2 — (2) MM-2. Natural gas fitting. Requires four years’ experience. Install, alter, repair, service and maintain natural gas piping and fittings; install hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; steam and hot water boilers; may connect water to existing valved outlets; warm air heating systems including chimney connections, flues, refractories, burners, fittings valves, thermal insulation, accessories and incidental piping; warm air appliances and other listed gas appliances; incidental controls and control wiring, pneumatic control systems; includes all required excavating, trenching and backfilling. May not install LP Gas systems.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MM 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-3 — (3) MM-3. Heating, ventilation & air conditioning (HVAC). Requires four years’ experience. Install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping, including fans, coils, condensing units, self-contained packaged air conditioning or heating units, evaporative cooling units, and ductwork and accessories including solar air heating and cooled mechanical air handling and 14.6.6 NMAC 8
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MM 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-4 — (4) MM-4. Heating, cooling and process piping. Requires four years’ experience. Install, alter, repair, service and maintain hydronic heating, cooling and process piping, piping and appurtenances for steam and hot water systems of any temperature or pressure range, chilled water systems, condensing water systems and other process piping systems; includes air handling equipment, pressure vessels, heat exchangers, boilers, refrigeration water chillers, cooling towers, fuel oil tanks and fuel oil piping; electric controls and control wiring not to exceed 24 volts; install high pressure and process piping solar thermal energy systems of any temperature or pressure range conveying gas or fluids other than potable water; water based fire protection sprinkler systems, dry chemical fire protection systems.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MM 98
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-98 — (5) MM-98. Mechanical. Requires four years’ experience. Indicates licensure in individual classifications MM-1 through MM-4 and covers all work described in these classifications, as well as work described in the MS-3, MS-6, MS-12 and MS-14. C. Mechanical Specialty classifications:
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MS 12

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-12 — (3) MS-12. Fire protection sprinkler systems. Requires four years’ experience. Install alter, repair, service or maintain water-based fire protection systems required pressure or storage tanks, controls and control wiring up to 24 volts; excavate and backfill and install piping from structure to off-site water supply adjacent to fire protection system property; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a validly licensed contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-12 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MS 14

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-14 — (4) MS-14. Dry chemical fire protection. Requires four years’ experience. Install, alter, repair, or service or maintain gaseous or chemical based fire protection systems including carbon dioxide (CO), or clean agents; pressurized storage tanks, valves, temperature sensing devices, solenoid or safety shut-off devices and other incidental controls and control wiring up to 24 volts; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a properly licensed contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-14 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MS 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-3 — (1) MS-3. Septic tanks & sewer. Requires two years’ experience. Install, alter, repair, service or maintain septic tanks and private sewage disposal systems, manholes and sewer lines, beginning at a connection to a public or private utility and ending at a point five feet beyond the outside wall of a building or structured; excavate, trench, backfill and grade as necessary; install or repair incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Addition of a new qualifying party/classification — MS 6

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-6 — (2) MS-6. Lawn sprinklers. Requires two years’ experience. Install, alter, repair, service or maintain potable water sprinkler systems; excavate, trench, backfill and grade as necessary; backflow prevention devices incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-6 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
New contractor license following revocation
No examination is required for this applicant pathway.
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Qualifying Party
Employ or be owned by a CID-certified qualifying party in every requested classification. This route uses an already issued, eligible certificate rather than first-issuance examination scores.
Revocation
Wait at least one year after the revocation order and do not violate CILA during the revocation; submit a new ordinary application.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.

Official no-examination sources

Effective from 2026-09-22.

Licensure after unlicensed contracting within the preceding year
No examination is required for this applicant pathway.
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Prior Unlicensed Work
Director must find no monetary damage or unresolved complaint; pay the additional statutory assessment and satisfy all ordinary license requirements.
Qualifying Party
Employ or be owned by a CID-certified qualifying party in every requested classification. This route uses an already issued, eligible certificate rather than first-issuance examination scores.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.

Official no-examination sources

Effective from 2026-09-22.

Reinstatement of a suspended or revoked contractor license
No examination is required for this applicant pathway.
Approval
CID/commission must approve restoration; further payment default may result in additional discipline.
Eligibility
Remain eligible under all other provisions. This route restores an existing eligible record; a new certificate application or retest after expiration follows the separate recertification route.
Penalties
Pay assessed fees and administrative penalties, or obtain a commission-approved payment plan with good-faith payments.

Official no-examination sources

Effective from 2026-09-22.

Initial licensure with an existing certified qualifying party
No examination is required for this applicant pathway.
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Qualifying Party
Employ or be owned by a CID-certified qualifying party in every requested classification. This route uses an already issued, eligible certificate rather than first-issuance examination scores.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.

Official no-examination sources

Effective from 2026-09-22.

Joint venture licensure
No examination is required for this applicant pathway.
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Qualifying Party
Employ or be owned by a CID-certified qualifying party in every requested classification. This route uses an already issued, eligible certificate rather than first-issuance examination scores.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Venture Members
Each member must have a valid New Mexico contractor license and be authorized to do business in New Mexico.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.

Official no-examination sources

Effective from 2026-09-22.

Late renewal of a suspended license within ninety days
No examination is required for this applicant pathway.
Application
Provide a complete notarized renewal, applicable fee, bond continuation or new bond, and current information.
Certificate
Retain qualifying parties in all licensed classifications and obtain their signatures.
Compliance
Maintain legal authority to do business, workers’ compensation compliance, financial responsibility and child-support compliance.
Late Fees
Within the grace period, pay the specified late fees; beyond ninety days the license is canceled and a new application is required.
Time
Current PSI instructions use a three-year cycle; renewal is due by expiration and late renewal is allowed within ninety days.

Official no-examination sources

Effective from 2026-09-22.

Expedited military licensure
No examination is required for this applicant pathway.
Application
Submit a complete application, military/family-status documents and background check if required.
Eligibility
Military service member, eligible spouse or dependent child, surviving spouse, or honorably discharged veteran as defined in §60-13-14.1(F).
Fee Waiver
Initial license/certificate fees are waived for the first three years; other applicable document or replacement charges remain.
Issuance
Issue as soon as practicable, no later than thirty days after a complete qualifying application.
Prior License
Hold a current good-standing license or certificate from another jurisdiction, including the armed forces, with substantially equivalent minimum requirements.
Renewal
The ordinary issuance and renewal requirements apply at renewal; the issued license is not provisional.

Official no-examination sources

Effective from 2026-09-22.

Initial contractor licensure with a newly certified qualifying party — EE 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EE-98 — (a) EE-98. Residential, and commercial and industrial electrical wiring 5000 volts, nominal or less. Requires four years’ experience. Includes all electrical systems and wiring methods operating at 5000 volts, nominal, or less; electrical systems and wiring methods identified in electrical specialty classifications ES-1, ES-2, ES-3 and ES-7 ES-10R, or ES-10 residential electrical systems and wiring methods identified in classification ER-1; trenching and ductwork associated with classification EL-1; associated excavating, trenching, boring, shoring, backfilling, compacting for all electrical systems and wiring methods of 5000 volts, nominal or less. Does not include electrical wiring defined in the EL-1 classification other than trenching and duct work as specified above.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the electrical NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in EE-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — EL 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EL-1 — (c) EL-1. Electrical distribution and transmission systems over 5000 volts, nominal. Requires four years’ experience. Includes all electrical systems and wiring methods operating at over 5000 volts, nominal; overhead or underground electrical distribution and transmission circuits, equipment,; associated towers, tower foundations and other supporting structures; associated excavating, trenching, boring, shoring, backfilling, compacting and ductwork; sub-stations and terminal facilities. Does not include any electrical wiring specified or other electrical classifications EE-98, ER-1, ES-1, ES-2, ES-3, ES-7, ES-10R or ES-10. (2) Electrical Specialty licenses.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in EL-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ER 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ER-1 — (b) ER-1. Residential electrical wiring 5000 volts, nominal or less. Requires two years’ experience. Includes electrical systems and wiring methods of 5000 volts, nominal or less at residential one and two-family dwelling units; multi-family dwellings when all such units are all on the ground floor with no occupancies above or below, as set forth in 14.10.4 NMAC. Does not include wiring for commercial use, such as motels, hotels and similar occupancies. May not contract for more than four dwelling units in any single building or structure.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ER-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ES 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-1 — (a) ES-1. Electrical signs and outline lighting. Requires two years’ experience. Installation at commercial locations only. Outline lighting is an arrangement of LED, incandescent lamps, or gaseous tubes to outline and call attention to certain features such as the shape of a building or the decoration of a window and may or may not contribute to the general illumination of an area. Includes commercial electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the sign or outline lighting where a “sign circuit” or outline lighting circuit has been provided within 10 feet of the roof or wall of the structure supporting the sign or outline lighting; concrete for the foundation of poles; build structures for the support of such signs associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the “sign circuit” not to exceed 10 feet from the foundation of the sign. 14.6.6 NMAC 6
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ES 10

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10 — (f) ES-10. Water well pump installer. Requires two years’ experience. Commercial water well pumps, 600 volts or less, single or three phase. Includes the installation, maintenance, repairing or replacing electrical equipment, wiring, and accessories directly associated with water well pump systems; variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation and trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment. Does not include systems over 600 volts, electrical services, building wiring or any other electrical wiring.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-10 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ES 10R

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10R — (e) ES-10R. Residential water well pump installer. Requires two years’ experience. Residential water well pumps, 120/240 volts or less, single phase 15 HP or less. Includes the installation, maintenance, repairing or replacement of electrical equipment, wiring, and accessories directly associated with water well pump systems; single phase variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation, trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment; does not include electrical systems over 240 volts, pumps over 15 HP, electrical services, building wiring or any other electrical wiring.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-10R and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ES 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-2 — (b) ES-2. Cathodic protection and lightening protection systems. Requires two years’ experience. Includes interior and exterior cathodic protection and lightening protection systems at commercial and residential locations; electrical wiring methods of 5000 volts, nominal or less required to complete a cathodic grounding protection system only; electrical wiring methods of 5000 volts, nominal or less required to complete a lightening protection system only. May not install the service riser, main service or service grounding.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ES 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-3 — (c) ES-3. Low voltage special systems (under 50 volts). Requires two years’ experience. Interior and exterior special systems, cabling and interconnections at commercial and residential locations, privately and publically owned operating at 50 volts or less; includes telecommunications systems; fire alarm systems, CATV systems; audio and visual systems; security systems; door and gate operated control circuits; temperature control circuits, other low voltage specialty systems operating at 50 volts or less; low voltage special systems cables installed in plenum or non-plenum rated walls or ceilings; low voltage special systems cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial low voltage special systems cables; overhead low voltage special systems cabling to structures; terminations and splicing of low voltage special system conductors; associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods required to complete any of the special systems listed above. An installer of television receive-only (TVROs) (dishes) is not required to have a contractor’s license when the installation is in a single-family dwelling and does not require the use of 120 volts for tracking. Does not include interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 or ER-1 classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — ES 7

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-7 — (d) ES-7. Telephone communication systems. Requires two years’ experience. Interior and exterior telecommunications cabling and interconnections at commercial and residential locations, in publicly or privately owned buildings; includes telecommunication cables installed in plenum or non-plenum rated walls or ceilings; telecommunication cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial telecommunication cables; overhead telecommunication cabling to structures; terminations and splicing of communication conductors; associated excavating trenching, boring, shoring, backfilling, compacting, installation of underground electrical wiring methods required to complete the installation of telecommunications systems; terminal facilities; installation of integrated services digital network cross connect equipment; installation of VoIP switching technology equipment, repeaters, including the installation of instruments at their terminating locations. Does not include Interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in ES-7 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GA 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-1 — (1) GA-1. Streets, roads and highways, including tunnels, parking lots, alleys, seal coat and surfacing. Requires two years’ experience. Clear, align, fill, compress, compact, build up or remove earth and do all work necessary to prepare, within the assigned rights-of-way, the land to accept a streets, roads, highways including culverts and tunnels, and alleys; includes parking lots, sidewalks or driveways; place and finish concrete or bituminous materials and apply sealcoat. This classification includes the scopes of work authorized by GA-2 and GA-3.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GA 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-2 — (2) GA-2. Maintenance and repair. Requires two years’ experience. Fix, maintain, repair, patch, mend, cover, fill or replace with materials of like substances to that currently existing on streets, roads, highways, parking lots, driveways, sidewalks and alleys; apply seal coat to driveways and parking lots. Install rumble strips.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GA 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-3 — (3) GA-3. Curbs, gutters and driveway culverts. Requires two years’ experience. Form, place and finish concrete curbs, gutters, driveway culverts, public sidewalks and bituminous ridge curbs for the deflection of water.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GA 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-4 — (4) GA-4. Striping. Requires two years’ experience. Paint directional stripes on paved roads, streets, highways, alleys and parking lots; install auto parking bumpers or stops and highway lane markers/reflectors.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GA 5

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-5 — (5) GA-5. Highway signs and guard rails. Requires two years’ experience. Erect and stabilize signs and guard rails along public highways, streets, roads and alleys, which are used for the direction and safety of vehicular traffic. Electrical signs must be installed by a properly licensed electrical contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-5 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GA 98
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-98 — (6) GA-98. Asphalt, bitumen and concrete construction. Indicates licensure in classifications GA-1 through GA-5; and covers all work authorized in those classifications. B. Residential and commercial building.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
Four years under the May 2025 QP application for GA-98
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GA-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GB 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-2 — (1) GB-2. Residential. Requires two years’ of foreman level practical or related trade experience. Erect, alter, repair or demolish residences and apartment houses accommodating not more than four family units, Groups R-1, R-2 and R-3, as those groups are defined in 14.7.2 NMAC; items included in Group U, as defined in 14.7.2 NMAC, when incidental to these structures; includes all work described by the GS specialty classifications, provided the work is limited to residential construction as defined under this provision.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GB-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GB 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-98 — (2) GB-98. General building. Requires four years of foreman level practical or related trade experience of which at two years must be commercial experience. Erect, alter, repair or demolish residential and commercial buildings, and certain structures; includes all work authorized by the GB-2, GF-5, GF-7 and GS classifications; seal coating and striping of driveways and parking lots; excludes those structures covered by the EE, MM, GA or GF classifications. C. Fixed works. Construct, alter or repair fixed or public works facilities; provided, however, that work in any trade or craft that is authorized by any one, or a combination of, the mechanical, electrical, or general building or LP Gas classifications must be performed by an entity validly licensed in the appropriate classification. Except as may be expressly provided in a specific classification description, fixed works licensees may not construct buildings that are primarily for the use and occupancy of the general public, but may bid and contract for such buildings when they are incidental to a fixed works project; however, such work must be subcontracted pursuant to Subsection B of 14.6.6.8 NMAC, above. Incidental storage buildings used exclusively for storage and not for occupancy are allowed within these classifications. 14.6.6 NMAC 2
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
Four years of foreman-level practical or related trade experience, including two years of commercial experience.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the general construction NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GB-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-1 — (1) GF-1. Airports. Requires two years’ experience. Construct, alter and repair airports, including excavating, grading, compacting, sub-surfacing, surfacing (dirt or bitumen and concrete), marking and other work on surfaces to be used for aircraft traffic, landing, take-off and taxi.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-2 — (2) GF-2. Bridges. Requires two years’ experience. Erect, construct, alter, repair or demolish any bridge, overpass or underpass, culvert or ramp, generally used for vehicular traffic.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-3 — (3) GF-3. Canals, reservoirs, dams and irrigation systems. Requires two years’ experience. Construct, erect, alter, repair, or demolish canals, dams, reservoirs irrigation systems; excavate, ditch, fill, compact and place pre-cast components, waterproof membranes and liners, concrete reinforcement, abutments and buttresses in connection therewith; install tanks, pumps, pipelines and substations incidental to the project; irrigation activities and piping when applicable solely to the production of agriculture or maintenance of livestock on a farm or ranch, excluding electrical work, are exempt from licensing requirements.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-4 — (4) GF-4. Drainage or flood control systems. Requires two years’ experience. Construct, erect, install, repair and alter drainage or flood control systems; dig, excavate, fill, prepare embankments for such purposes, place pre-cast components, concrete reinforcement and perform all other work incidental to these projects.; install storm sewers, including trenching, boring, shoring, backfilling, compacting, and paving.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 5

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-5 — (5) GF-5. Recreation areas. Requires two years’ experience. Construct, prepare, clear, repair or alter facilities for use as recreation areas, including but not limited to golf courses, driving ranges, water parks, tennis courts, playgrounds, outdoor athletic facilities, miniature golf courses, pitch-and-putt golf courses; prepare the area by excavation, fill, including foundations, retaining walls, sprinkler systems, rest benches, shade and rain shelters and foot bridges relative to recreation areas; public campgrounds and parks or similar facilities, including toilet facilities and lean-tos.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-5 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 6

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-6 — (6) GF-6. Railroad and tunnel construction. Requires two years’ experience. Construct railroad lines, including clearing, filling, shaping, compacting, placing rip-rap, stabilizing, setting roadbeds, ties, tie plates, rails, rail connectors, frogs, switch plates, switches, and all appurtenances necessary for an operational railroad line, including bridges, culverts, tunnels, retaining walls, dikes, gates, tool sheds and landing or parking platforms for equipment. Includes welding operations necessary for rail construction.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-6 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 7

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-7 — (7) GF-7. Tanks and towers. Requires two years’ experience. Construct or fabricate on site and install tanks for the storage of solids or liquids, above or below ground, and towers such as radio, television and telecommunications towers, including all necessary site-work, excavation and construction of concrete tanks, pads and foundations, cutting, welding, placement of structural members, engineered structural support systems for elevated tanks, and engineered or prefabricated towers; includes the repair and placement of liners in tanks, and incidental storage buildings.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-7 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 8

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-8 — (8) GF-8. Transmission lines, tanks and substations (non-electrical). Requires two years’ experience. Build, construct and place lines for the transmission or conveyance of natural gas or petroleum, water and other fluid substances, including the application of protective coatings, trenching, boring, shoring, backfilling, compacting, paving and surfacing necessary and incidental to the completion of the installation of such facilities. Includes incidental buildings, tanks, and substations required for the project; construct, alter or repair industrial plants, including, but not limited to, refineries and power generation plants.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-8 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 9

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-9 — (9) GF-9. Utility lines and systems (sewage, water, natural gas and underground telephone cables). Requires two years’ experience. Construct, install, alter or repair utility lines and utility systems for the transmission of sewage, natural gas and water, including excavating, grading, trenching, boring, shoring, backfilling, compacting, paving and surfacing; includes tanks, pumps, lift-stations and substations incidental to the project; construct, alter, or repair treatment plants and facilities incidental thereto; install direct burial communications cable by trenching, direct plowing or pulling direct burial cable through existing raceways and install vaults as directed by the telecommunications utility; associated excavating, trenching, boring, shoring, backfilling, compacting, paving and surfacing. Shall not perform installation of electrical raceways including directional boring or pipe jacking methods, splicing, termination, installation of load pots, installation of integrated services digital network cross connect equipment, installation of VoIP switching technology equipment, overhead cabling work, or other activities considered under the scope of the ES-7, EL-1, ES-3 or EE-98 electrical classifications.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-9 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GF 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-98 — (10) GF-98. Construct, alter or repair fixed works facilities. Requires four years’ experience; indicates licensure in classifications GF-1 through GF-9 and authorizes all work described in these classifications. D. General Specialty classifications. General construction includes numerous specialties. Therefore, CID has established the GS classification series to enable entities that perform this kind of work to be 14.6.6 NMAC 3
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GF-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 1
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-1 — (1) GS-1. Acoustical insulation and insulation. Requires two years’ experience. Install any insulating material, including urethane foam and approved waterproof membranes and coatings, in or on buildings, structures and on piping for the purpose of energy conservation, temperature and sound control, and fireproofing. Does not include the installation of urethane roof systems.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 13

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-13 — (8) GS-13. Framing. Requires two years of foreman level practical or related trade experience; cut, join, install wood, metal or other products approved by the division and utilized for the framing of a structure or building, including bearing and non-bearing walls, rafters, headers, trusses, joists, studs, door and window rough frames, and roof decks, including repair to any of the above.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-13 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 14
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-14 — (9) GS-14. Windows, doors and skylights. Requires two years’ experience. Fabricate and install windows and doors in buildings and structures, including the necessary installation of window, door and skylight framing, and the installation of necessary hardware; cut, assemble and install glass work, and execute the glazing of frames, panels, sash and doors; fabricate and install storm doors, windows, and skylights including flashing; does not include structural alterations to enlarge any opening.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-14 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Vendor Door Exam
The April 2026 PSI bulletin names GS-6 Door Installation, whereas the March 2022 codified classification is GS-14 Windows, doors and skylights. Neither source explicitly assigns the GS-6 paper to GS-14; that association is undetermined and is not inferred from topic overlap.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 15
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-15 — (10) GS-15. Caissons, piers and pile driving. Requires two years’ experience. Install piers, caissons and pilings through the use of pile driving equipment and machinery, including necessary excavation, grading and clearing for site preparation for pile driving activities; cut, weld, join and fabricate caissons or piles; install all necessary concrete and reinforcing steel within the caissons to create a structural member; soil stabilization and rock-fall mitigation.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-15 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 16

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-16 — (11) GS-16. Masonry. Requires two years’ experience. Install or erect brick and other baked clay products, rough cut and dressed stone, artificial stone and pre-cast blocks, structural glass brick or block adobe, laid at random or in courses, with or without mortar, to form masonry walls, anchored stone or masonry veneer, including building walls, freestanding walls six feet or higher from ground level and retaining walls measuring thirty-six inches or more measured from the bottom of the footing; does not include the execution, fabrication and erecting of poured cement and concrete, except as a foundation for a wall. 14.6.6 NMAC 4
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-16 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 2
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-2 — (2) GS-2. Awnings and canopies. Requires two years’ experience. Construct, erect and install awnings and canopies, attached to buildings and structures or free standing, including, but not limited to carports and service station canopies, and including necessary excavation and foundation work. All electrical work shall be performed by a properly licensed electrical contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 21

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-21 — (12) GS-21. Roofing. Requires two years of foreman level practical or related trade experience. Install, alter or repair roof systems on new or existing roof decks to create a weatherproof and waterproof protective membrane, with or without insulation, using asphalt, pitch, tar, sealants, felt, shakes, shingles, roof tile, slate, urethane or any other approved materials including the preparatory work necessary to bring a roof deck or an existing roof to a condition where roofing can be installed, and sealed or repaired; includes cutting, shaping, fabricating, and installing of sheet metal such as cornices, flashing, skylights (excluding alterations to structural framing), roof coatings, gutters, leaders, rainwater downspouts, pans, prefabricated chimneys, at or near roof lines, metal flues, or doing any part of any combination thereof, which relate to and are incidental to roofing projects.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-21 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 23
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-23 — (13) GS-23. Sign construction (non-electrical). Requires two years’ experience. Fabricate on site, install and erect signs of wood, steel, plastic or any material, or any combination of materials, which are to be embedded in the earth, in concrete or other base material, or attached to buildings or structures using anchors, attached cables, bars or similar devices and appurtenances; electrified signs shall only be installed by contractors holding an ES-1 or an EE-98 classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-23 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 24

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-24 — (14) GS-24. Structural steel erection. Requires two years of foreman level practical or related trade experience. Fabricate on site and erect structural steel shapes and plates, of any profile, perimeter or cross-section that may be used as structural members for buildings and structures, including riveting and welding; does not authorize construction of concrete foundations or complete buildings.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years of foreman level practical or related trade experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-24 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 25

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-25 — (15) GS-25. Swimming pools (non-plumbing, mechanical or electrical). Requires two years’ experience. Construct and repair swimming pools including excavation, installation of reinforcing steel or mesh, application of concrete and special coatings; shall not perform any scope of work which is authorized by a plumbing, mechanical, electrical or LP Gas classification.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-25 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 29
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-29 — (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
up to four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-29 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 30

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-30 — (16) GS-30. Plastering, stucco and lathing. Requires two years’ experience. Prepare wall and ceiling surfaces, interior or exterior, with wood, metal lath, wallboard or other properly prepared surfaces which will accept and hold a mixture of sand, plaster (including gypsum plaster), lime and water, or sand and cement with water or any combination of materials to create a permanent surface coating; these coatings may be applied manually or mechanically on surfaces which will support such coating; install steel or wood or other division approved stud systems (non-structural), channel iron work and affix lath or any other materials or products, prepared or manufactured to provide a base for such coatings.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-30 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 31
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-31 — (17) GS-31. Siding. Requires two years’ experience. Apply, replace, or repair siding consisting of slate, gypsum, wood, plastics or other products, including the application of furred up networks on which the siding can be installed.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-31 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 32
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-32 — (18) GS-32. Miscellaneous sheet metal. Requires two years’ experience. Fabricate on site and install sheet metal (galvanized iron) such as cornices, flashing, gutters, leaders, rainwater downspouts, pans, and prefabricated chimneys; shall not install heating, ventilation & air conditioning (HVAC) duct systems, vents, grease hoods, or other appurtenances that are authorized by mechanical or plumbing classifications.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-32 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 34
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-34 — (19) GS-34. Concrete coring, drilling and slab sawing. Requires two years’ experience. Coring, boring, drilling, cutting, and sawing concrete, including the removal or demolition of the material; does not include the installation of electrical wiring or plumbing in such bored, drilled, cut or sawed concrete. (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis. [14.6.6.9 NMAC - Rp, 14.6.6.9 NMAC, 3/10/2022]
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-34 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-4 — (3) GS-4. Concrete, cement, walkways and driveways. Requires two years’ experience practical trade experience, one year of which must be foreman level. Mix, pour, place, and finish concrete,; includes all necessary preparatory work including excavation, form work, and placing of reinforcement materials; includes the installation on private property of curbs, gutters, sidewalks, and driveway culverts; may not perform this work in public rights-of-way unless subcontracted to a validly licensed GA licensee.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
Two years of practical trade experience, including one year at foreman level.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 5
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-5 — (4) GS-5. Demolition. Requires two years’ experience. Demolish all or any portion of a buildings and structures authorized by the GB-98 classification, including demolition to portions of buildings and structures allowing additions and alterations to be completed to the remaining portions of the building or structure.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-5 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 7

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-7 — (5) GS-7. Drywall installation and texture. Requires two years’ experience. Installation of gypsum wallboard, and gypsum sheathing; includes taping, bedding and coating the surfaces of the wallboard and sheathing with gypsum joint systems, tape and drywall mud, or a combination of other materials to create a permanent surface or coating and of walls and ceilings; install steel or wood stud systems (non-structural) and channel iron work to provide a base for the application of drywall.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-7 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 8

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-8 — (6) GS-8. Earthmoving, excavating and ditching. Requires two years’ experience. Perform earthwork associated with or incidental to construction projects regulated by CID, using hand or power tools, machines that use air, fluids, or other material under pressure, or heavy equipment, in such a manner that cutting, filling, excavating, grading, trenching, backfilling, boring and any similar excavating activity can be executed; earthmoving, excavating and ditching activities applicable to the preparation and production of agriculture or maintenance of livestock on a farm or ranch are exempt from licensing requirements.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-8 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — GS 9

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-9 — (7) GS-9. Elevators, escalators, and related machinery (non-electrical). Requires two years’ experience. Erect, install or repair elevators, escalators and related machinery, including sheave beams, sheaves, cable and wire rope, guides, cab, counterweights, doors, including sidewalk elevators, automatic and manual controls, signal systems and all other devices, apparatus, machinery and equipment (including fabrication on job site) essential to the safe and efficient installation and operation of electrical, hydraulic and manually operated elevators and escalators and conveyors designed specifically for the transportation of people.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in GS-9 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MM 1

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-1 — (1) MM-1. Plumbing. Requires four years’ experience. Install, alter, repair, service, and maintain plumbing, plumbing fixtures, and piping, includes incidental concrete supports, and excavating, trenching and backfilling; includes hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; piping for fuel, oil and gasoline; piping and appurtenances for solar thermal energy systems; potable water irrigation sprinkler systems; swimming pools and spas; includes pneumatic or electric controls and control wiring not greater than 24 volts; septic tanks, manholes and sewer lines; does not include installation of natural gas fired appliances or natural gas piping; piping and agricultural sprinkler irrigation system installation and maintenance on farm or ranch property that moves water for livestock use or irrigation purposes from a privately owned well or pipeline, not connected to a public potable water supply are exempt from licensing requirements. When connected to a potable water source all connections must be downstream of an approved back flow prevention device. If a backflow prevention device is required it shall be permitted and installed by a properly certified journeyman employed by an appropriately licensed contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-1 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MM 2

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-2 — (2) MM-2. Natural gas fitting. Requires four years’ experience. Install, alter, repair, service and maintain natural gas piping and fittings; install hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; steam and hot water boilers; may connect water to existing valved outlets; warm air heating systems including chimney connections, flues, refractories, burners, fittings valves, thermal insulation, accessories and incidental piping; warm air appliances and other listed gas appliances; incidental controls and control wiring, pneumatic control systems; includes all required excavating, trenching and backfilling. May not install LP Gas systems.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-2 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MM 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-3 — (3) MM-3. Heating, ventilation & air conditioning (HVAC). Requires four years’ experience. Install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping, including fans, coils, condensing units, self-contained packaged air conditioning or heating units, evaporative cooling units, and ductwork and accessories including solar air heating and cooled mechanical air handling and 14.6.6 NMAC 8
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MM 4

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-4 — (4) MM-4. Heating, cooling and process piping. Requires four years’ experience. Install, alter, repair, service and maintain hydronic heating, cooling and process piping, piping and appurtenances for steam and hot water systems of any temperature or pressure range, chilled water systems, condensing water systems and other process piping systems; includes air handling equipment, pressure vessels, heat exchangers, boilers, refrigeration water chillers, cooling towers, fuel oil tanks and fuel oil piping; electric controls and control wiring not to exceed 24 volts; install high pressure and process piping solar thermal energy systems of any temperature or pressure range conveying gas or fluids other than potable water; water based fire protection sprinkler systems, dry chemical fire protection systems.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-4 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MM 98
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-98 — (5) MM-98. Mechanical. Requires four years’ experience. Indicates licensure in individual classifications MM-1 through MM-4 and covers all work described in these classifications, as well as work described in the MS-3, MS-6, MS-12 and MS-14. C. Mechanical Specialty classifications:
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MM-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MS 12

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-12 — (3) MS-12. Fire protection sprinkler systems. Requires four years’ experience. Install alter, repair, service or maintain water-based fire protection systems required pressure or storage tanks, controls and control wiring up to 24 volts; excavate and backfill and install piping from structure to off-site water supply adjacent to fire protection system property; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a validly licensed contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-12 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MS 14

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-14 — (4) MS-14. Dry chemical fire protection. Requires four years’ experience. Install, alter, repair, or service or maintain gaseous or chemical based fire protection systems including carbon dioxide (CO), or clean agents; pressurized storage tanks, valves, temperature sensing devices, solenoid or safety shut-off devices and other incidental controls and control wiring up to 24 volts; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a properly licensed contractor.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-14 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MS 3

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-3 — (1) MS-3. Septic tanks & sewer. Requires two years’ experience. Install, alter, repair, service or maintain septic tanks and private sewage disposal systems, manholes and sewer lines, beginning at a connection to a public or private utility and ending at a point five feet beyond the outside wall of a building or structured; excavate, trench, backfill and grade as necessary; install or repair incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-3 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — MS 6

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-6 — (2) MS-6. Lawn sprinklers. Requires two years’ experience. Install, alter, repair, service or maintain potable water sprinkler systems; excavate, trench, backfill and grade as necessary; backflow prevention devices incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
two years’ experience
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in MS-6 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Reinstatement after child support suspension or revocation
No examination is required for this applicant pathway.
Compliance Certificate
Submit the human services department certificate of compliance and pay amounts owed to CID.
Expiry Limit
If more than ninety days have passed since expiration of a revoked license, apply for a new license instead; the one-year revocation wait is waived.
Other Grounds
Reinstatement is unavailable if independent grounds for suspension or revocation remain.

Official no-examination sources

Effective from 2026-09-22.

Timely license renewal
No examination is required for this applicant pathway.
Application
Provide a complete notarized renewal, applicable fee, bond continuation or new bond, and current information.
Certificate
Retain qualifying parties in all licensed classifications and obtain their signatures.
Compliance
Maintain legal authority to do business, workers’ compensation compliance, financial responsibility and child-support compliance.
Late Fees
Within the grace period, pay the specified late fees; beyond ninety days the license is canceled and a new application is required.
Time
Renew before expiration.

Official no-examination sources

Effective from 2026-09-22.

Elevator Contractor License

Contractor license to perform work on conveyances under the Elevator Safety Act; qualified mechanics perform the conveyance work.

Licensing authority: New Mexico Regulation and Licensing Department, Construction Industries Division, Elevator Safety Bureau · Application information

Addition of a new qualifying party/classification — EV 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EV-98 — EV-98 Elevators, Escalators, Conveyors. Requires four years of experience.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years of experience
Experience Alternatives
Four years (8,000 hours), or completion of NAEC CETT or the IUEC program with a mechanic’s card; those program credentials waive the experience affidavit, not the EV98 exam.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in EV-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Initial contractor licensure with a newly certified qualifying party — EV 98

All of the following:

Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EV-98 — EV-98 Elevators, Escalators, Conveyors. Requires four years of experience.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Experience
four years of experience
Experience Alternatives
Four years (8,000 hours), or completion of NAEC CETT or the IUEC program with a mechanic’s card; those program credentials waive the experience affidavit, not the EV98 exam.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Minimum Age
At least eighteen years old.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Qualifying Party
This route certifies a new qualifying party in EV-98 and submits the passing scores/course certificate for first certificate issuance with the contractor application or status change.
Score Validity
Passing examination scores are valid for one year.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Work Recency
Required practical/trade experience must be within the ten years before application.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.
Elevator contractor licensure with an existing EV98 qualifying party
No examination is required for this applicant pathway.
Application
Submit the complete signed and notarized application, fees and supporting documents to PSI.
Conduct
Disqualifying convictions, unresolved disciplinary matters, unlicensed activity and child-support noncompliance may prevent approval.
Entity Registration
Be legally authorized to do business in New Mexico; corporations, LLCs and partnerships submit Secretary of State registration as applicable.
Financial Responsibility
Maintain a $10,000 code bond covering the full license term.
Name
Obtain approval of the proposed name; it must not imply an unauthorized trade.
Ownership Age
The majority of the business may not be owned by an individual aged seventeen or younger.
Qualifying Party
Employ or be owned by a CID-certified qualifying party in every requested classification. This route uses an already issued, eligible certificate rather than first-issuance examination scores.
Scope
Conveyance installation, alteration, servicing, repair, testing, erection, maintenance, removal or dismantling; work performed by appropriately certified mechanics or supervised apprentices.
Tax Registration
Submit current New Mexico Taxation and Revenue registration in the applicant’s exact name.
Workers Compensation
Comply with workers’ compensation requirements. The May 2025 contractor application states that a sole proprietor without employees may be exempt.

Official no-examination sources

Effective from 2026-09-22.

Elevator contractor license renewal
No examination is required for this applicant pathway.
Application
Provide a complete notarized renewal, applicable fee, bond continuation or new bond, and current information.
Certificate
Retain qualifying parties in all licensed classifications and obtain their signatures.
Compliance
Maintain legal authority to do business, workers’ compensation compliance, financial responsibility and child-support compliance.
Late Fees
Within the grace period, pay the specified late fees; beyond ninety days the license is canceled and a new application is required.
Time
Current PSI instructions use a three-year cycle; renewal is due by expiration and late renewal is allowed within ninety days.

Official no-examination sources

Effective from 2026-09-22.

Certificate of Qualification

Individual qualifying-party certification for specified contractor classifications; the entity must hold its own contractor license.

Licensing authority: New Mexico Regulation and Licensing Department, Construction Industries Division · Application information

Additional classification for an active qualifying party — EE 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
EE-98 — (a) EE-98. Residential, and commercial and industrial electrical wiring 5000 volts, nominal or less. Requires four years’ experience. Includes all electrical systems and wiring methods operating at 5000 volts, nominal, or less; electrical systems and wiring methods identified in electrical specialty classifications ES-1, ES-2, ES-3 and ES-7 ES-10R, or ES-10 residential electrical systems and wiring methods identified in classification ER-1; trenching and ductwork associated with classification EL-1; associated excavating, trenching, boring, shoring, backfilling, compacting for all electrical systems and wiring methods of 5000 volts, nominal or less. Does not include electrical wiring defined in the EL-1 classification other than trenching and duct work as specified above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the electrical NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — EL 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
EL-1 — (c) EL-1. Electrical distribution and transmission systems over 5000 volts, nominal. Requires four years’ experience. Includes all electrical systems and wiring methods operating at over 5000 volts, nominal; overhead or underground electrical distribution and transmission circuits, equipment,; associated towers, tower foundations and other supporting structures; associated excavating, trenching, boring, shoring, backfilling, compacting and ductwork; sub-stations and terminal facilities. Does not include any electrical wiring specified or other electrical classifications EE-98, ER-1, ES-1, ES-2, ES-3, ES-7, ES-10R or ES-10. (2) Electrical Specialty licenses.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ER 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ER-1 — (b) ER-1. Residential electrical wiring 5000 volts, nominal or less. Requires two years’ experience. Includes electrical systems and wiring methods of 5000 volts, nominal or less at residential one and two-family dwelling units; multi-family dwellings when all such units are all on the ground floor with no occupancies above or below, as set forth in 14.10.4 NMAC. Does not include wiring for commercial use, such as motels, hotels and similar occupancies. May not contract for more than four dwelling units in any single building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ES 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ES-1 — (a) ES-1. Electrical signs and outline lighting. Requires two years’ experience. Installation at commercial locations only. Outline lighting is an arrangement of LED, incandescent lamps, or gaseous tubes to outline and call attention to certain features such as the shape of a building or the decoration of a window and may or may not contribute to the general illumination of an area. Includes commercial electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the sign or outline lighting where a “sign circuit” or outline lighting circuit has been provided within 10 feet of the roof or wall of the structure supporting the sign or outline lighting; concrete for the foundation of poles; build structures for the support of such signs associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the “sign circuit” not to exceed 10 feet from the foundation of the sign. 14.6.6 NMAC 6
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ES 10

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ES-10 — (f) ES-10. Water well pump installer. Requires two years’ experience. Commercial water well pumps, 600 volts or less, single or three phase. Includes the installation, maintenance, repairing or replacing electrical equipment, wiring, and accessories directly associated with water well pump systems; variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation and trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment. Does not include systems over 600 volts, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ES 10R

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ES-10R — (e) ES-10R. Residential water well pump installer. Requires two years’ experience. Residential water well pumps, 120/240 volts or less, single phase 15 HP or less. Includes the installation, maintenance, repairing or replacement of electrical equipment, wiring, and accessories directly associated with water well pump systems; single phase variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation, trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment; does not include electrical systems over 240 volts, pumps over 15 HP, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ES 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ES-2 — (b) ES-2. Cathodic protection and lightening protection systems. Requires two years’ experience. Includes interior and exterior cathodic protection and lightening protection systems at commercial and residential locations; electrical wiring methods of 5000 volts, nominal or less required to complete a cathodic grounding protection system only; electrical wiring methods of 5000 volts, nominal or less required to complete a lightening protection system only. May not install the service riser, main service or service grounding.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ES 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ES-3 — (c) ES-3. Low voltage special systems (under 50 volts). Requires two years’ experience. Interior and exterior special systems, cabling and interconnections at commercial and residential locations, privately and publically owned operating at 50 volts or less; includes telecommunications systems; fire alarm systems, CATV systems; audio and visual systems; security systems; door and gate operated control circuits; temperature control circuits, other low voltage specialty systems operating at 50 volts or less; low voltage special systems cables installed in plenum or non-plenum rated walls or ceilings; low voltage special systems cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial low voltage special systems cables; overhead low voltage special systems cabling to structures; terminations and splicing of low voltage special system conductors; associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods required to complete any of the special systems listed above. An installer of television receive-only (TVROs) (dishes) is not required to have a contractor’s license when the installation is in a single-family dwelling and does not require the use of 120 volts for tracking. Does not include interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 or ER-1 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — ES 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
ES-7 — (d) ES-7. Telephone communication systems. Requires two years’ experience. Interior and exterior telecommunications cabling and interconnections at commercial and residential locations, in publicly or privately owned buildings; includes telecommunication cables installed in plenum or non-plenum rated walls or ceilings; telecommunication cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial telecommunication cables; overhead telecommunication cabling to structures; terminations and splicing of communication conductors; associated excavating trenching, boring, shoring, backfilling, compacting, installation of underground electrical wiring methods required to complete the installation of telecommunications systems; terminal facilities; installation of integrated services digital network cross connect equipment; installation of VoIP switching technology equipment, repeaters, including the installation of instruments at their terminating locations. Does not include Interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — EV 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
EV-98 — EV-98 Elevators, Escalators, Conveyors. Requires four years of experience.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years of experience
Experience Alternatives
Four years (8,000 hours), or completion of NAEC CETT or the IUEC program with a mechanic’s card; those program credentials waive the experience affidavit, not the EV98 exam.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GA 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GA-1 — (1) GA-1. Streets, roads and highways, including tunnels, parking lots, alleys, seal coat and surfacing. Requires two years’ experience. Clear, align, fill, compress, compact, build up or remove earth and do all work necessary to prepare, within the assigned rights-of-way, the land to accept a streets, roads, highways including culverts and tunnels, and alleys; includes parking lots, sidewalks or driveways; place and finish concrete or bituminous materials and apply sealcoat. This classification includes the scopes of work authorized by GA-2 and GA-3.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GA 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GA-2 — (2) GA-2. Maintenance and repair. Requires two years’ experience. Fix, maintain, repair, patch, mend, cover, fill or replace with materials of like substances to that currently existing on streets, roads, highways, parking lots, driveways, sidewalks and alleys; apply seal coat to driveways and parking lots. Install rumble strips.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GA 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GA-3 — (3) GA-3. Curbs, gutters and driveway culverts. Requires two years’ experience. Form, place and finish concrete curbs, gutters, driveway culverts, public sidewalks and bituminous ridge curbs for the deflection of water.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GA 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GA-4 — (4) GA-4. Striping. Requires two years’ experience. Paint directional stripes on paved roads, streets, highways, alleys and parking lots; install auto parking bumpers or stops and highway lane markers/reflectors.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GA 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GA-5 — (5) GA-5. Highway signs and guard rails. Requires two years’ experience. Erect and stabilize signs and guard rails along public highways, streets, roads and alleys, which are used for the direction and safety of vehicular traffic. Electrical signs must be installed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GA 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GA-98 — (6) GA-98. Asphalt, bitumen and concrete construction. Indicates licensure in classifications GA-1 through GA-5; and covers all work authorized in those classifications. B. Residential and commercial building.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Four years under the May 2025 QP application for GA-98
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GB 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GB-2 — (1) GB-2. Residential. Requires two years’ of foreman level practical or related trade experience. Erect, alter, repair or demolish residences and apartment houses accommodating not more than four family units, Groups R-1, R-2 and R-3, as those groups are defined in 14.7.2 NMAC; items included in Group U, as defined in 14.7.2 NMAC, when incidental to these structures; includes all work described by the GS specialty classifications, provided the work is limited to residential construction as defined under this provision.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GB 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GB-98 — (2) GB-98. General building. Requires four years of foreman level practical or related trade experience of which at two years must be commercial experience. Erect, alter, repair or demolish residential and commercial buildings, and certain structures; includes all work authorized by the GB-2, GF-5, GF-7 and GS classifications; seal coating and striping of driveways and parking lots; excludes those structures covered by the EE, MM, GA or GF classifications. C. Fixed works. Construct, alter or repair fixed or public works facilities; provided, however, that work in any trade or craft that is authorized by any one, or a combination of, the mechanical, electrical, or general building or LP Gas classifications must be performed by an entity validly licensed in the appropriate classification. Except as may be expressly provided in a specific classification description, fixed works licensees may not construct buildings that are primarily for the use and occupancy of the general public, but may bid and contract for such buildings when they are incidental to a fixed works project; however, such work must be subcontracted pursuant to Subsection B of 14.6.6.8 NMAC, above. Incidental storage buildings used exclusively for storage and not for occupancy are allowed within these classifications. 14.6.6 NMAC 2
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Four years of foreman-level practical or related trade experience, including two years of commercial experience.
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the general construction NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-1 — (1) GF-1. Airports. Requires two years’ experience. Construct, alter and repair airports, including excavating, grading, compacting, sub-surfacing, surfacing (dirt or bitumen and concrete), marking and other work on surfaces to be used for aircraft traffic, landing, take-off and taxi.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-2 — (2) GF-2. Bridges. Requires two years’ experience. Erect, construct, alter, repair or demolish any bridge, overpass or underpass, culvert or ramp, generally used for vehicular traffic.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-3 — (3) GF-3. Canals, reservoirs, dams and irrigation systems. Requires two years’ experience. Construct, erect, alter, repair, or demolish canals, dams, reservoirs irrigation systems; excavate, ditch, fill, compact and place pre-cast components, waterproof membranes and liners, concrete reinforcement, abutments and buttresses in connection therewith; install tanks, pumps, pipelines and substations incidental to the project; irrigation activities and piping when applicable solely to the production of agriculture or maintenance of livestock on a farm or ranch, excluding electrical work, are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-4 — (4) GF-4. Drainage or flood control systems. Requires two years’ experience. Construct, erect, install, repair and alter drainage or flood control systems; dig, excavate, fill, prepare embankments for such purposes, place pre-cast components, concrete reinforcement and perform all other work incidental to these projects.; install storm sewers, including trenching, boring, shoring, backfilling, compacting, and paving.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-5 — (5) GF-5. Recreation areas. Requires two years’ experience. Construct, prepare, clear, repair or alter facilities for use as recreation areas, including but not limited to golf courses, driving ranges, water parks, tennis courts, playgrounds, outdoor athletic facilities, miniature golf courses, pitch-and-putt golf courses; prepare the area by excavation, fill, including foundations, retaining walls, sprinkler systems, rest benches, shade and rain shelters and foot bridges relative to recreation areas; public campgrounds and parks or similar facilities, including toilet facilities and lean-tos.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-6 — (6) GF-6. Railroad and tunnel construction. Requires two years’ experience. Construct railroad lines, including clearing, filling, shaping, compacting, placing rip-rap, stabilizing, setting roadbeds, ties, tie plates, rails, rail connectors, frogs, switch plates, switches, and all appurtenances necessary for an operational railroad line, including bridges, culverts, tunnels, retaining walls, dikes, gates, tool sheds and landing or parking platforms for equipment. Includes welding operations necessary for rail construction.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-7 — (7) GF-7. Tanks and towers. Requires two years’ experience. Construct or fabricate on site and install tanks for the storage of solids or liquids, above or below ground, and towers such as radio, television and telecommunications towers, including all necessary site-work, excavation and construction of concrete tanks, pads and foundations, cutting, welding, placement of structural members, engineered structural support systems for elevated tanks, and engineered or prefabricated towers; includes the repair and placement of liners in tanks, and incidental storage buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-8 — (8) GF-8. Transmission lines, tanks and substations (non-electrical). Requires two years’ experience. Build, construct and place lines for the transmission or conveyance of natural gas or petroleum, water and other fluid substances, including the application of protective coatings, trenching, boring, shoring, backfilling, compacting, paving and surfacing necessary and incidental to the completion of the installation of such facilities. Includes incidental buildings, tanks, and substations required for the project; construct, alter or repair industrial plants, including, but not limited to, refineries and power generation plants.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-9 — (9) GF-9. Utility lines and systems (sewage, water, natural gas and underground telephone cables). Requires two years’ experience. Construct, install, alter or repair utility lines and utility systems for the transmission of sewage, natural gas and water, including excavating, grading, trenching, boring, shoring, backfilling, compacting, paving and surfacing; includes tanks, pumps, lift-stations and substations incidental to the project; construct, alter, or repair treatment plants and facilities incidental thereto; install direct burial communications cable by trenching, direct plowing or pulling direct burial cable through existing raceways and install vaults as directed by the telecommunications utility; associated excavating, trenching, boring, shoring, backfilling, compacting, paving and surfacing. Shall not perform installation of electrical raceways including directional boring or pipe jacking methods, splicing, termination, installation of load pots, installation of integrated services digital network cross connect equipment, installation of VoIP switching technology equipment, overhead cabling work, or other activities considered under the scope of the ES-7, EL-1, ES-3 or EE-98 electrical classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GF 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GF-98 — (10) GF-98. Construct, alter or repair fixed works facilities. Requires four years’ experience; indicates licensure in classifications GF-1 through GF-9 and authorizes all work described in these classifications. D. General Specialty classifications. General construction includes numerous specialties. Therefore, CID has established the GS classification series to enable entities that perform this kind of work to be 14.6.6 NMAC 3
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 1
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-1 — (1) GS-1. Acoustical insulation and insulation. Requires two years’ experience. Install any insulating material, including urethane foam and approved waterproof membranes and coatings, in or on buildings, structures and on piping for the purpose of energy conservation, temperature and sound control, and fireproofing. Does not include the installation of urethane roof systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 13

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-13 — (8) GS-13. Framing. Requires two years of foreman level practical or related trade experience; cut, join, install wood, metal or other products approved by the division and utilized for the framing of a structure or building, including bearing and non-bearing walls, rafters, headers, trusses, joists, studs, door and window rough frames, and roof decks, including repair to any of the above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 14
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-14 — (9) GS-14. Windows, doors and skylights. Requires two years’ experience. Fabricate and install windows and doors in buildings and structures, including the necessary installation of window, door and skylight framing, and the installation of necessary hardware; cut, assemble and install glass work, and execute the glazing of frames, panels, sash and doors; fabricate and install storm doors, windows, and skylights including flashing; does not include structural alterations to enlarge any opening.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Vendor Door Exam
The April 2026 PSI bulletin names GS-6 Door Installation, whereas the March 2022 codified classification is GS-14 Windows, doors and skylights. Neither source explicitly assigns the GS-6 paper to GS-14; that association is undetermined and is not inferred from topic overlap.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 15
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-15 — (10) GS-15. Caissons, piers and pile driving. Requires two years’ experience. Install piers, caissons and pilings through the use of pile driving equipment and machinery, including necessary excavation, grading and clearing for site preparation for pile driving activities; cut, weld, join and fabricate caissons or piles; install all necessary concrete and reinforcing steel within the caissons to create a structural member; soil stabilization and rock-fall mitigation.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 16

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-16 — (11) GS-16. Masonry. Requires two years’ experience. Install or erect brick and other baked clay products, rough cut and dressed stone, artificial stone and pre-cast blocks, structural glass brick or block adobe, laid at random or in courses, with or without mortar, to form masonry walls, anchored stone or masonry veneer, including building walls, freestanding walls six feet or higher from ground level and retaining walls measuring thirty-six inches or more measured from the bottom of the footing; does not include the execution, fabrication and erecting of poured cement and concrete, except as a foundation for a wall. 14.6.6 NMAC 4
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 2
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-2 — (2) GS-2. Awnings and canopies. Requires two years’ experience. Construct, erect and install awnings and canopies, attached to buildings and structures or free standing, including, but not limited to carports and service station canopies, and including necessary excavation and foundation work. All electrical work shall be performed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 21

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-21 — (12) GS-21. Roofing. Requires two years of foreman level practical or related trade experience. Install, alter or repair roof systems on new or existing roof decks to create a weatherproof and waterproof protective membrane, with or without insulation, using asphalt, pitch, tar, sealants, felt, shakes, shingles, roof tile, slate, urethane or any other approved materials including the preparatory work necessary to bring a roof deck or an existing roof to a condition where roofing can be installed, and sealed or repaired; includes cutting, shaping, fabricating, and installing of sheet metal such as cornices, flashing, skylights (excluding alterations to structural framing), roof coatings, gutters, leaders, rainwater downspouts, pans, prefabricated chimneys, at or near roof lines, metal flues, or doing any part of any combination thereof, which relate to and are incidental to roofing projects.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 23
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-23 — (13) GS-23. Sign construction (non-electrical). Requires two years’ experience. Fabricate on site, install and erect signs of wood, steel, plastic or any material, or any combination of materials, which are to be embedded in the earth, in concrete or other base material, or attached to buildings or structures using anchors, attached cables, bars or similar devices and appurtenances; electrified signs shall only be installed by contractors holding an ES-1 or an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 24

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-24 — (14) GS-24. Structural steel erection. Requires two years of foreman level practical or related trade experience. Fabricate on site and erect structural steel shapes and plates, of any profile, perimeter or cross-section that may be used as structural members for buildings and structures, including riveting and welding; does not authorize construction of concrete foundations or complete buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 25

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-25 — (15) GS-25. Swimming pools (non-plumbing, mechanical or electrical). Requires two years’ experience. Construct and repair swimming pools including excavation, installation of reinforcing steel or mesh, application of concrete and special coatings; shall not perform any scope of work which is authorized by a plumbing, mechanical, electrical or LP Gas classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 29
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-29 — (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
up to four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 30

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-30 — (16) GS-30. Plastering, stucco and lathing. Requires two years’ experience. Prepare wall and ceiling surfaces, interior or exterior, with wood, metal lath, wallboard or other properly prepared surfaces which will accept and hold a mixture of sand, plaster (including gypsum plaster), lime and water, or sand and cement with water or any combination of materials to create a permanent surface coating; these coatings may be applied manually or mechanically on surfaces which will support such coating; install steel or wood or other division approved stud systems (non-structural), channel iron work and affix lath or any other materials or products, prepared or manufactured to provide a base for such coatings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 31
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-31 — (17) GS-31. Siding. Requires two years’ experience. Apply, replace, or repair siding consisting of slate, gypsum, wood, plastics or other products, including the application of furred up networks on which the siding can be installed.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 32
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-32 — (18) GS-32. Miscellaneous sheet metal. Requires two years’ experience. Fabricate on site and install sheet metal (galvanized iron) such as cornices, flashing, gutters, leaders, rainwater downspouts, pans, and prefabricated chimneys; shall not install heating, ventilation & air conditioning (HVAC) duct systems, vents, grease hoods, or other appurtenances that are authorized by mechanical or plumbing classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 34
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-34 — (19) GS-34. Concrete coring, drilling and slab sawing. Requires two years’ experience. Coring, boring, drilling, cutting, and sawing concrete, including the removal or demolition of the material; does not include the installation of electrical wiring or plumbing in such bored, drilled, cut or sawed concrete. (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis. [14.6.6.9 NMAC - Rp, 14.6.6.9 NMAC, 3/10/2022]
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-4 — (3) GS-4. Concrete, cement, walkways and driveways. Requires two years’ experience practical trade experience, one year of which must be foreman level. Mix, pour, place, and finish concrete,; includes all necessary preparatory work including excavation, form work, and placing of reinforcement materials; includes the installation on private property of curbs, gutters, sidewalks, and driveway culverts; may not perform this work in public rights-of-way unless subcontracted to a validly licensed GA licensee.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Two years of practical trade experience, including one year at foreman level.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 5
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-5 — (4) GS-5. Demolition. Requires two years’ experience. Demolish all or any portion of a buildings and structures authorized by the GB-98 classification, including demolition to portions of buildings and structures allowing additions and alterations to be completed to the remaining portions of the building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-7 — (5) GS-7. Drywall installation and texture. Requires two years’ experience. Installation of gypsum wallboard, and gypsum sheathing; includes taping, bedding and coating the surfaces of the wallboard and sheathing with gypsum joint systems, tape and drywall mud, or a combination of other materials to create a permanent surface or coating and of walls and ceilings; install steel or wood stud systems (non-structural) and channel iron work to provide a base for the application of drywall.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-8 — (6) GS-8. Earthmoving, excavating and ditching. Requires two years’ experience. Perform earthwork associated with or incidental to construction projects regulated by CID, using hand or power tools, machines that use air, fluids, or other material under pressure, or heavy equipment, in such a manner that cutting, filling, excavating, grading, trenching, backfilling, boring and any similar excavating activity can be executed; earthmoving, excavating and ditching activities applicable to the preparation and production of agriculture or maintenance of livestock on a farm or ranch are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — GS 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
GS-9 — (7) GS-9. Elevators, escalators, and related machinery (non-electrical). Requires two years’ experience. Erect, install or repair elevators, escalators and related machinery, including sheave beams, sheaves, cable and wire rope, guides, cab, counterweights, doors, including sidewalk elevators, automatic and manual controls, signal systems and all other devices, apparatus, machinery and equipment (including fabrication on job site) essential to the safe and efficient installation and operation of electrical, hydraulic and manually operated elevators and escalators and conveyors designed specifically for the transportation of people.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MM 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MM-1 — (1) MM-1. Plumbing. Requires four years’ experience. Install, alter, repair, service, and maintain plumbing, plumbing fixtures, and piping, includes incidental concrete supports, and excavating, trenching and backfilling; includes hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; piping for fuel, oil and gasoline; piping and appurtenances for solar thermal energy systems; potable water irrigation sprinkler systems; swimming pools and spas; includes pneumatic or electric controls and control wiring not greater than 24 volts; septic tanks, manholes and sewer lines; does not include installation of natural gas fired appliances or natural gas piping; piping and agricultural sprinkler irrigation system installation and maintenance on farm or ranch property that moves water for livestock use or irrigation purposes from a privately owned well or pipeline, not connected to a public potable water supply are exempt from licensing requirements. When connected to a potable water source all connections must be downstream of an approved back flow prevention device. If a backflow prevention device is required it shall be permitted and installed by a properly certified journeyman employed by an appropriately licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MM 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MM-2 — (2) MM-2. Natural gas fitting. Requires four years’ experience. Install, alter, repair, service and maintain natural gas piping and fittings; install hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; steam and hot water boilers; may connect water to existing valved outlets; warm air heating systems including chimney connections, flues, refractories, burners, fittings valves, thermal insulation, accessories and incidental piping; warm air appliances and other listed gas appliances; incidental controls and control wiring, pneumatic control systems; includes all required excavating, trenching and backfilling. May not install LP Gas systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MM 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MM-3 — (3) MM-3. Heating, ventilation & air conditioning (HVAC). Requires four years’ experience. Install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping, including fans, coils, condensing units, self-contained packaged air conditioning or heating units, evaporative cooling units, and ductwork and accessories including solar air heating and cooled mechanical air handling and 14.6.6 NMAC 8
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MM 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MM-4 — (4) MM-4. Heating, cooling and process piping. Requires four years’ experience. Install, alter, repair, service and maintain hydronic heating, cooling and process piping, piping and appurtenances for steam and hot water systems of any temperature or pressure range, chilled water systems, condensing water systems and other process piping systems; includes air handling equipment, pressure vessels, heat exchangers, boilers, refrigeration water chillers, cooling towers, fuel oil tanks and fuel oil piping; electric controls and control wiring not to exceed 24 volts; install high pressure and process piping solar thermal energy systems of any temperature or pressure range conveying gas or fluids other than potable water; water based fire protection sprinkler systems, dry chemical fire protection systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MM 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MM-98 — (5) MM-98. Mechanical. Requires four years’ experience. Indicates licensure in individual classifications MM-1 through MM-4 and covers all work described in these classifications, as well as work described in the MS-3, MS-6, MS-12 and MS-14. C. Mechanical Specialty classifications:
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MS 12

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MS-12 — (3) MS-12. Fire protection sprinkler systems. Requires four years’ experience. Install alter, repair, service or maintain water-based fire protection systems required pressure or storage tanks, controls and control wiring up to 24 volts; excavate and backfill and install piping from structure to off-site water supply adjacent to fire protection system property; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a validly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MS 14

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MS-14 — (4) MS-14. Dry chemical fire protection. Requires four years’ experience. Install, alter, repair, or service or maintain gaseous or chemical based fire protection systems including carbon dioxide (CO), or clean agents; pressurized storage tanks, valves, temperature sensing devices, solenoid or safety shut-off devices and other incidental controls and control wiring up to 24 volts; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a properly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MS 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MS-3 — (1) MS-3. Septic tanks & sewer. Requires two years’ experience. Install, alter, repair, service or maintain septic tanks and private sewage disposal systems, manholes and sewer lines, beginning at a connection to a public or private utility and ending at a point five feet beyond the outside wall of a building or structured; excavate, trench, backfill and grade as necessary; install or repair incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Additional classification for an active qualifying party — MS 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Business Law Implementation
PSI Contractor Licensing FAQ question 7 states: "Business & Law exam is not required for active QPs." This removes a new sitting for that applicant; the statutory examination remains a leaf and the existing qualification/course is an applicant condition.
Classification
MS-6 — (2) MS-6. Lawn sprinklers. Requires two years’ experience. Install, alter, repair, service or maintain potable water sprinkler systems; excavate, trench, backfill and grade as necessary; backflow prevention devices incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Current Certificate
Applicant is already an active QP and seeks a new classification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Reinstatement of a suspended or revoked qualifying party certificate
No examination is required for this applicant pathway.
Approval
CID/commission must approve restoration; further payment default may result in additional discipline.
Eligibility
Remain eligible under all other provisions. This route restores an existing eligible record; a new certificate application or retest after expiration follows the separate recertification route.
Penalties
Pay assessed fees and administrative penalties, or obtain a commission-approved payment plan with good-faith payments.

Official no-examination sources

Effective from 2026-09-22.

Initial qualifying party certification — EE 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EE-98 — (a) EE-98. Residential, and commercial and industrial electrical wiring 5000 volts, nominal or less. Requires four years’ experience. Includes all electrical systems and wiring methods operating at 5000 volts, nominal, or less; electrical systems and wiring methods identified in electrical specialty classifications ES-1, ES-2, ES-3 and ES-7 ES-10R, or ES-10 residential electrical systems and wiring methods identified in classification ER-1; trenching and ductwork associated with classification EL-1; associated excavating, trenching, boring, shoring, backfilling, compacting for all electrical systems and wiring methods of 5000 volts, nominal or less. Does not include electrical wiring defined in the EL-1 classification other than trenching and duct work as specified above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the electrical NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — EL 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EL-1 — (c) EL-1. Electrical distribution and transmission systems over 5000 volts, nominal. Requires four years’ experience. Includes all electrical systems and wiring methods operating at over 5000 volts, nominal; overhead or underground electrical distribution and transmission circuits, equipment,; associated towers, tower foundations and other supporting structures; associated excavating, trenching, boring, shoring, backfilling, compacting and ductwork; sub-stations and terminal facilities. Does not include any electrical wiring specified or other electrical classifications EE-98, ER-1, ES-1, ES-2, ES-3, ES-7, ES-10R or ES-10. (2) Electrical Specialty licenses.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ER 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ER-1 — (b) ER-1. Residential electrical wiring 5000 volts, nominal or less. Requires two years’ experience. Includes electrical systems and wiring methods of 5000 volts, nominal or less at residential one and two-family dwelling units; multi-family dwellings when all such units are all on the ground floor with no occupancies above or below, as set forth in 14.10.4 NMAC. Does not include wiring for commercial use, such as motels, hotels and similar occupancies. May not contract for more than four dwelling units in any single building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ES 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-1 — (a) ES-1. Electrical signs and outline lighting. Requires two years’ experience. Installation at commercial locations only. Outline lighting is an arrangement of LED, incandescent lamps, or gaseous tubes to outline and call attention to certain features such as the shape of a building or the decoration of a window and may or may not contribute to the general illumination of an area. Includes commercial electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the sign or outline lighting where a “sign circuit” or outline lighting circuit has been provided within 10 feet of the roof or wall of the structure supporting the sign or outline lighting; concrete for the foundation of poles; build structures for the support of such signs associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the “sign circuit” not to exceed 10 feet from the foundation of the sign. 14.6.6 NMAC 6
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ES 10

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10 — (f) ES-10. Water well pump installer. Requires two years’ experience. Commercial water well pumps, 600 volts or less, single or three phase. Includes the installation, maintenance, repairing or replacing electrical equipment, wiring, and accessories directly associated with water well pump systems; variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation and trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment. Does not include systems over 600 volts, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ES 10R

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10R — (e) ES-10R. Residential water well pump installer. Requires two years’ experience. Residential water well pumps, 120/240 volts or less, single phase 15 HP or less. Includes the installation, maintenance, repairing or replacement of electrical equipment, wiring, and accessories directly associated with water well pump systems; single phase variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation, trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment; does not include electrical systems over 240 volts, pumps over 15 HP, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ES 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-2 — (b) ES-2. Cathodic protection and lightening protection systems. Requires two years’ experience. Includes interior and exterior cathodic protection and lightening protection systems at commercial and residential locations; electrical wiring methods of 5000 volts, nominal or less required to complete a cathodic grounding protection system only; electrical wiring methods of 5000 volts, nominal or less required to complete a lightening protection system only. May not install the service riser, main service or service grounding.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ES 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-3 — (c) ES-3. Low voltage special systems (under 50 volts). Requires two years’ experience. Interior and exterior special systems, cabling and interconnections at commercial and residential locations, privately and publically owned operating at 50 volts or less; includes telecommunications systems; fire alarm systems, CATV systems; audio and visual systems; security systems; door and gate operated control circuits; temperature control circuits, other low voltage specialty systems operating at 50 volts or less; low voltage special systems cables installed in plenum or non-plenum rated walls or ceilings; low voltage special systems cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial low voltage special systems cables; overhead low voltage special systems cabling to structures; terminations and splicing of low voltage special system conductors; associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods required to complete any of the special systems listed above. An installer of television receive-only (TVROs) (dishes) is not required to have a contractor’s license when the installation is in a single-family dwelling and does not require the use of 120 volts for tracking. Does not include interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 or ER-1 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — ES 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-7 — (d) ES-7. Telephone communication systems. Requires two years’ experience. Interior and exterior telecommunications cabling and interconnections at commercial and residential locations, in publicly or privately owned buildings; includes telecommunication cables installed in plenum or non-plenum rated walls or ceilings; telecommunication cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial telecommunication cables; overhead telecommunication cabling to structures; terminations and splicing of communication conductors; associated excavating trenching, boring, shoring, backfilling, compacting, installation of underground electrical wiring methods required to complete the installation of telecommunications systems; terminal facilities; installation of integrated services digital network cross connect equipment; installation of VoIP switching technology equipment, repeaters, including the installation of instruments at their terminating locations. Does not include Interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — EV 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EV-98 — EV-98 Elevators, Escalators, Conveyors. Requires four years of experience.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years of experience
Experience Alternatives
Four years (8,000 hours), or completion of NAEC CETT or the IUEC program with a mechanic’s card; those program credentials waive the experience affidavit, not the EV98 exam.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GA 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-1 — (1) GA-1. Streets, roads and highways, including tunnels, parking lots, alleys, seal coat and surfacing. Requires two years’ experience. Clear, align, fill, compress, compact, build up or remove earth and do all work necessary to prepare, within the assigned rights-of-way, the land to accept a streets, roads, highways including culverts and tunnels, and alleys; includes parking lots, sidewalks or driveways; place and finish concrete or bituminous materials and apply sealcoat. This classification includes the scopes of work authorized by GA-2 and GA-3.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GA 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-2 — (2) GA-2. Maintenance and repair. Requires two years’ experience. Fix, maintain, repair, patch, mend, cover, fill or replace with materials of like substances to that currently existing on streets, roads, highways, parking lots, driveways, sidewalks and alleys; apply seal coat to driveways and parking lots. Install rumble strips.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GA 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-3 — (3) GA-3. Curbs, gutters and driveway culverts. Requires two years’ experience. Form, place and finish concrete curbs, gutters, driveway culverts, public sidewalks and bituminous ridge curbs for the deflection of water.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GA 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-4 — (4) GA-4. Striping. Requires two years’ experience. Paint directional stripes on paved roads, streets, highways, alleys and parking lots; install auto parking bumpers or stops and highway lane markers/reflectors.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GA 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-5 — (5) GA-5. Highway signs and guard rails. Requires two years’ experience. Erect and stabilize signs and guard rails along public highways, streets, roads and alleys, which are used for the direction and safety of vehicular traffic. Electrical signs must be installed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GA 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-98 — (6) GA-98. Asphalt, bitumen and concrete construction. Indicates licensure in classifications GA-1 through GA-5; and covers all work authorized in those classifications. B. Residential and commercial building.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Four years under the May 2025 QP application for GA-98
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GB 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-2 — (1) GB-2. Residential. Requires two years’ of foreman level practical or related trade experience. Erect, alter, repair or demolish residences and apartment houses accommodating not more than four family units, Groups R-1, R-2 and R-3, as those groups are defined in 14.7.2 NMAC; items included in Group U, as defined in 14.7.2 NMAC, when incidental to these structures; includes all work described by the GS specialty classifications, provided the work is limited to residential construction as defined under this provision.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GB 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-98 — (2) GB-98. General building. Requires four years of foreman level practical or related trade experience of which at two years must be commercial experience. Erect, alter, repair or demolish residential and commercial buildings, and certain structures; includes all work authorized by the GB-2, GF-5, GF-7 and GS classifications; seal coating and striping of driveways and parking lots; excludes those structures covered by the EE, MM, GA or GF classifications. C. Fixed works. Construct, alter or repair fixed or public works facilities; provided, however, that work in any trade or craft that is authorized by any one, or a combination of, the mechanical, electrical, or general building or LP Gas classifications must be performed by an entity validly licensed in the appropriate classification. Except as may be expressly provided in a specific classification description, fixed works licensees may not construct buildings that are primarily for the use and occupancy of the general public, but may bid and contract for such buildings when they are incidental to a fixed works project; however, such work must be subcontracted pursuant to Subsection B of 14.6.6.8 NMAC, above. Incidental storage buildings used exclusively for storage and not for occupancy are allowed within these classifications. 14.6.6 NMAC 2
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Four years of foreman-level practical or related trade experience, including two years of commercial experience.
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the general construction NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-1 — (1) GF-1. Airports. Requires two years’ experience. Construct, alter and repair airports, including excavating, grading, compacting, sub-surfacing, surfacing (dirt or bitumen and concrete), marking and other work on surfaces to be used for aircraft traffic, landing, take-off and taxi.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-2 — (2) GF-2. Bridges. Requires two years’ experience. Erect, construct, alter, repair or demolish any bridge, overpass or underpass, culvert or ramp, generally used for vehicular traffic.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-3 — (3) GF-3. Canals, reservoirs, dams and irrigation systems. Requires two years’ experience. Construct, erect, alter, repair, or demolish canals, dams, reservoirs irrigation systems; excavate, ditch, fill, compact and place pre-cast components, waterproof membranes and liners, concrete reinforcement, abutments and buttresses in connection therewith; install tanks, pumps, pipelines and substations incidental to the project; irrigation activities and piping when applicable solely to the production of agriculture or maintenance of livestock on a farm or ranch, excluding electrical work, are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-4 — (4) GF-4. Drainage or flood control systems. Requires two years’ experience. Construct, erect, install, repair and alter drainage or flood control systems; dig, excavate, fill, prepare embankments for such purposes, place pre-cast components, concrete reinforcement and perform all other work incidental to these projects.; install storm sewers, including trenching, boring, shoring, backfilling, compacting, and paving.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-5 — (5) GF-5. Recreation areas. Requires two years’ experience. Construct, prepare, clear, repair or alter facilities for use as recreation areas, including but not limited to golf courses, driving ranges, water parks, tennis courts, playgrounds, outdoor athletic facilities, miniature golf courses, pitch-and-putt golf courses; prepare the area by excavation, fill, including foundations, retaining walls, sprinkler systems, rest benches, shade and rain shelters and foot bridges relative to recreation areas; public campgrounds and parks or similar facilities, including toilet facilities and lean-tos.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-6 — (6) GF-6. Railroad and tunnel construction. Requires two years’ experience. Construct railroad lines, including clearing, filling, shaping, compacting, placing rip-rap, stabilizing, setting roadbeds, ties, tie plates, rails, rail connectors, frogs, switch plates, switches, and all appurtenances necessary for an operational railroad line, including bridges, culverts, tunnels, retaining walls, dikes, gates, tool sheds and landing or parking platforms for equipment. Includes welding operations necessary for rail construction.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-7 — (7) GF-7. Tanks and towers. Requires two years’ experience. Construct or fabricate on site and install tanks for the storage of solids or liquids, above or below ground, and towers such as radio, television and telecommunications towers, including all necessary site-work, excavation and construction of concrete tanks, pads and foundations, cutting, welding, placement of structural members, engineered structural support systems for elevated tanks, and engineered or prefabricated towers; includes the repair and placement of liners in tanks, and incidental storage buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-8 — (8) GF-8. Transmission lines, tanks and substations (non-electrical). Requires two years’ experience. Build, construct and place lines for the transmission or conveyance of natural gas or petroleum, water and other fluid substances, including the application of protective coatings, trenching, boring, shoring, backfilling, compacting, paving and surfacing necessary and incidental to the completion of the installation of such facilities. Includes incidental buildings, tanks, and substations required for the project; construct, alter or repair industrial plants, including, but not limited to, refineries and power generation plants.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-9 — (9) GF-9. Utility lines and systems (sewage, water, natural gas and underground telephone cables). Requires two years’ experience. Construct, install, alter or repair utility lines and utility systems for the transmission of sewage, natural gas and water, including excavating, grading, trenching, boring, shoring, backfilling, compacting, paving and surfacing; includes tanks, pumps, lift-stations and substations incidental to the project; construct, alter, or repair treatment plants and facilities incidental thereto; install direct burial communications cable by trenching, direct plowing or pulling direct burial cable through existing raceways and install vaults as directed by the telecommunications utility; associated excavating, trenching, boring, shoring, backfilling, compacting, paving and surfacing. Shall not perform installation of electrical raceways including directional boring or pipe jacking methods, splicing, termination, installation of load pots, installation of integrated services digital network cross connect equipment, installation of VoIP switching technology equipment, overhead cabling work, or other activities considered under the scope of the ES-7, EL-1, ES-3 or EE-98 electrical classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GF 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-98 — (10) GF-98. Construct, alter or repair fixed works facilities. Requires four years’ experience; indicates licensure in classifications GF-1 through GF-9 and authorizes all work described in these classifications. D. General Specialty classifications. General construction includes numerous specialties. Therefore, CID has established the GS classification series to enable entities that perform this kind of work to be 14.6.6 NMAC 3
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 1
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-1 — (1) GS-1. Acoustical insulation and insulation. Requires two years’ experience. Install any insulating material, including urethane foam and approved waterproof membranes and coatings, in or on buildings, structures and on piping for the purpose of energy conservation, temperature and sound control, and fireproofing. Does not include the installation of urethane roof systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 13

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-13 — (8) GS-13. Framing. Requires two years of foreman level practical or related trade experience; cut, join, install wood, metal or other products approved by the division and utilized for the framing of a structure or building, including bearing and non-bearing walls, rafters, headers, trusses, joists, studs, door and window rough frames, and roof decks, including repair to any of the above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 14
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-14 — (9) GS-14. Windows, doors and skylights. Requires two years’ experience. Fabricate and install windows and doors in buildings and structures, including the necessary installation of window, door and skylight framing, and the installation of necessary hardware; cut, assemble and install glass work, and execute the glazing of frames, panels, sash and doors; fabricate and install storm doors, windows, and skylights including flashing; does not include structural alterations to enlarge any opening.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Vendor Door Exam
The April 2026 PSI bulletin names GS-6 Door Installation, whereas the March 2022 codified classification is GS-14 Windows, doors and skylights. Neither source explicitly assigns the GS-6 paper to GS-14; that association is undetermined and is not inferred from topic overlap.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 15
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-15 — (10) GS-15. Caissons, piers and pile driving. Requires two years’ experience. Install piers, caissons and pilings through the use of pile driving equipment and machinery, including necessary excavation, grading and clearing for site preparation for pile driving activities; cut, weld, join and fabricate caissons or piles; install all necessary concrete and reinforcing steel within the caissons to create a structural member; soil stabilization and rock-fall mitigation.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 16

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-16 — (11) GS-16. Masonry. Requires two years’ experience. Install or erect brick and other baked clay products, rough cut and dressed stone, artificial stone and pre-cast blocks, structural glass brick or block adobe, laid at random or in courses, with or without mortar, to form masonry walls, anchored stone or masonry veneer, including building walls, freestanding walls six feet or higher from ground level and retaining walls measuring thirty-six inches or more measured from the bottom of the footing; does not include the execution, fabrication and erecting of poured cement and concrete, except as a foundation for a wall. 14.6.6 NMAC 4
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 2
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-2 — (2) GS-2. Awnings and canopies. Requires two years’ experience. Construct, erect and install awnings and canopies, attached to buildings and structures or free standing, including, but not limited to carports and service station canopies, and including necessary excavation and foundation work. All electrical work shall be performed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 21

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-21 — (12) GS-21. Roofing. Requires two years of foreman level practical or related trade experience. Install, alter or repair roof systems on new or existing roof decks to create a weatherproof and waterproof protective membrane, with or without insulation, using asphalt, pitch, tar, sealants, felt, shakes, shingles, roof tile, slate, urethane or any other approved materials including the preparatory work necessary to bring a roof deck or an existing roof to a condition where roofing can be installed, and sealed or repaired; includes cutting, shaping, fabricating, and installing of sheet metal such as cornices, flashing, skylights (excluding alterations to structural framing), roof coatings, gutters, leaders, rainwater downspouts, pans, prefabricated chimneys, at or near roof lines, metal flues, or doing any part of any combination thereof, which relate to and are incidental to roofing projects.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 23
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-23 — (13) GS-23. Sign construction (non-electrical). Requires two years’ experience. Fabricate on site, install and erect signs of wood, steel, plastic or any material, or any combination of materials, which are to be embedded in the earth, in concrete or other base material, or attached to buildings or structures using anchors, attached cables, bars or similar devices and appurtenances; electrified signs shall only be installed by contractors holding an ES-1 or an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 24

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-24 — (14) GS-24. Structural steel erection. Requires two years of foreman level practical or related trade experience. Fabricate on site and erect structural steel shapes and plates, of any profile, perimeter or cross-section that may be used as structural members for buildings and structures, including riveting and welding; does not authorize construction of concrete foundations or complete buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 25

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-25 — (15) GS-25. Swimming pools (non-plumbing, mechanical or electrical). Requires two years’ experience. Construct and repair swimming pools including excavation, installation of reinforcing steel or mesh, application of concrete and special coatings; shall not perform any scope of work which is authorized by a plumbing, mechanical, electrical or LP Gas classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 29
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-29 — (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
up to four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 30

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-30 — (16) GS-30. Plastering, stucco and lathing. Requires two years’ experience. Prepare wall and ceiling surfaces, interior or exterior, with wood, metal lath, wallboard or other properly prepared surfaces which will accept and hold a mixture of sand, plaster (including gypsum plaster), lime and water, or sand and cement with water or any combination of materials to create a permanent surface coating; these coatings may be applied manually or mechanically on surfaces which will support such coating; install steel or wood or other division approved stud systems (non-structural), channel iron work and affix lath or any other materials or products, prepared or manufactured to provide a base for such coatings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 31
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-31 — (17) GS-31. Siding. Requires two years’ experience. Apply, replace, or repair siding consisting of slate, gypsum, wood, plastics or other products, including the application of furred up networks on which the siding can be installed.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 32
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-32 — (18) GS-32. Miscellaneous sheet metal. Requires two years’ experience. Fabricate on site and install sheet metal (galvanized iron) such as cornices, flashing, gutters, leaders, rainwater downspouts, pans, and prefabricated chimneys; shall not install heating, ventilation & air conditioning (HVAC) duct systems, vents, grease hoods, or other appurtenances that are authorized by mechanical or plumbing classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 34
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-34 — (19) GS-34. Concrete coring, drilling and slab sawing. Requires two years’ experience. Coring, boring, drilling, cutting, and sawing concrete, including the removal or demolition of the material; does not include the installation of electrical wiring or plumbing in such bored, drilled, cut or sawed concrete. (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis. [14.6.6.9 NMAC - Rp, 14.6.6.9 NMAC, 3/10/2022]
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-4 — (3) GS-4. Concrete, cement, walkways and driveways. Requires two years’ experience practical trade experience, one year of which must be foreman level. Mix, pour, place, and finish concrete,; includes all necessary preparatory work including excavation, form work, and placing of reinforcement materials; includes the installation on private property of curbs, gutters, sidewalks, and driveway culverts; may not perform this work in public rights-of-way unless subcontracted to a validly licensed GA licensee.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Two years of practical trade experience, including one year at foreman level.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 5
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-5 — (4) GS-5. Demolition. Requires two years’ experience. Demolish all or any portion of a buildings and structures authorized by the GB-98 classification, including demolition to portions of buildings and structures allowing additions and alterations to be completed to the remaining portions of the building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-7 — (5) GS-7. Drywall installation and texture. Requires two years’ experience. Installation of gypsum wallboard, and gypsum sheathing; includes taping, bedding and coating the surfaces of the wallboard and sheathing with gypsum joint systems, tape and drywall mud, or a combination of other materials to create a permanent surface or coating and of walls and ceilings; install steel or wood stud systems (non-structural) and channel iron work to provide a base for the application of drywall.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-8 — (6) GS-8. Earthmoving, excavating and ditching. Requires two years’ experience. Perform earthwork associated with or incidental to construction projects regulated by CID, using hand or power tools, machines that use air, fluids, or other material under pressure, or heavy equipment, in such a manner that cutting, filling, excavating, grading, trenching, backfilling, boring and any similar excavating activity can be executed; earthmoving, excavating and ditching activities applicable to the preparation and production of agriculture or maintenance of livestock on a farm or ranch are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — GS 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-9 — (7) GS-9. Elevators, escalators, and related machinery (non-electrical). Requires two years’ experience. Erect, install or repair elevators, escalators and related machinery, including sheave beams, sheaves, cable and wire rope, guides, cab, counterweights, doors, including sidewalk elevators, automatic and manual controls, signal systems and all other devices, apparatus, machinery and equipment (including fabrication on job site) essential to the safe and efficient installation and operation of electrical, hydraulic and manually operated elevators and escalators and conveyors designed specifically for the transportation of people.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MM 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-1 — (1) MM-1. Plumbing. Requires four years’ experience. Install, alter, repair, service, and maintain plumbing, plumbing fixtures, and piping, includes incidental concrete supports, and excavating, trenching and backfilling; includes hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; piping for fuel, oil and gasoline; piping and appurtenances for solar thermal energy systems; potable water irrigation sprinkler systems; swimming pools and spas; includes pneumatic or electric controls and control wiring not greater than 24 volts; septic tanks, manholes and sewer lines; does not include installation of natural gas fired appliances or natural gas piping; piping and agricultural sprinkler irrigation system installation and maintenance on farm or ranch property that moves water for livestock use or irrigation purposes from a privately owned well or pipeline, not connected to a public potable water supply are exempt from licensing requirements. When connected to a potable water source all connections must be downstream of an approved back flow prevention device. If a backflow prevention device is required it shall be permitted and installed by a properly certified journeyman employed by an appropriately licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MM 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-2 — (2) MM-2. Natural gas fitting. Requires four years’ experience. Install, alter, repair, service and maintain natural gas piping and fittings; install hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; steam and hot water boilers; may connect water to existing valved outlets; warm air heating systems including chimney connections, flues, refractories, burners, fittings valves, thermal insulation, accessories and incidental piping; warm air appliances and other listed gas appliances; incidental controls and control wiring, pneumatic control systems; includes all required excavating, trenching and backfilling. May not install LP Gas systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MM 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-3 — (3) MM-3. Heating, ventilation & air conditioning (HVAC). Requires four years’ experience. Install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping, including fans, coils, condensing units, self-contained packaged air conditioning or heating units, evaporative cooling units, and ductwork and accessories including solar air heating and cooled mechanical air handling and 14.6.6 NMAC 8
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MM 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-4 — (4) MM-4. Heating, cooling and process piping. Requires four years’ experience. Install, alter, repair, service and maintain hydronic heating, cooling and process piping, piping and appurtenances for steam and hot water systems of any temperature or pressure range, chilled water systems, condensing water systems and other process piping systems; includes air handling equipment, pressure vessels, heat exchangers, boilers, refrigeration water chillers, cooling towers, fuel oil tanks and fuel oil piping; electric controls and control wiring not to exceed 24 volts; install high pressure and process piping solar thermal energy systems of any temperature or pressure range conveying gas or fluids other than potable water; water based fire protection sprinkler systems, dry chemical fire protection systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MM 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-98 — (5) MM-98. Mechanical. Requires four years’ experience. Indicates licensure in individual classifications MM-1 through MM-4 and covers all work described in these classifications, as well as work described in the MS-3, MS-6, MS-12 and MS-14. C. Mechanical Specialty classifications:
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MS 12

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-12 — (3) MS-12. Fire protection sprinkler systems. Requires four years’ experience. Install alter, repair, service or maintain water-based fire protection systems required pressure or storage tanks, controls and control wiring up to 24 volts; excavate and backfill and install piping from structure to off-site water supply adjacent to fire protection system property; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a validly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MS 14

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-14 — (4) MS-14. Dry chemical fire protection. Requires four years’ experience. Install, alter, repair, or service or maintain gaseous or chemical based fire protection systems including carbon dioxide (CO), or clean agents; pressurized storage tanks, valves, temperature sensing devices, solenoid or safety shut-off devices and other incidental controls and control wiring up to 24 volts; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a properly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MS 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-3 — (1) MS-3. Septic tanks & sewer. Requires two years’ experience. Install, alter, repair, service or maintain septic tanks and private sewage disposal systems, manholes and sewer lines, beginning at a connection to a public or private utility and ending at a point five feet beyond the outside wall of a building or structured; excavate, trench, backfill and grade as necessary; install or repair incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Initial qualifying party certification — MS 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-6 — (2) MS-6. Lawn sprinklers. Requires two years’ experience. Install, alter, repair, service or maintain potable water sprinkler systems; excavate, trench, backfill and grade as necessary; backflow prevention devices incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Expedited military qualifying party certification
No examination is required for this applicant pathway.
Application
Submit a complete application, military/family-status documents and background check if required.
Eligibility
Military service member, eligible spouse or dependent child, surviving spouse, or honorably discharged veteran as defined in §60-13-14.1(F).
Fee Waiver
Initial license/certificate fees are waived for the first three years; other applicable document or replacement charges remain.
Issuance
Issue as soon as practicable, no later than thirty days after a complete qualifying application.
Prior License
Hold a current good-standing license or certificate from another jurisdiction, including the armed forces, with substantially equivalent minimum requirements.
Renewal
The ordinary issuance and renewal requirements apply at renewal; the issued license is not provisional.

Official no-examination sources

Effective from 2026-09-22.

Reinstatement of a qualifying party certificate after child support enforcement
No examination is required for this applicant pathway.
Certificate Status
The certificate must otherwise remain eligible; expiration under 14.6.3.8(K) requires recertification.
Compliance Certificate
Provide the human services department certificate and pay amounts owed.
Other Grounds
Independent grounds for discipline remain effective.
Time Limit
Within two years of the qualifying-party revocation order; after that a new certificate application is required with the one-year wait waived.

Official no-examination sources

Effective from 2026-09-22.

Reattachment of an existing qualifying party certificate within its eligibility period
No examination is required for this applicant pathway.
Certificate
An existing unattached certificate must be within the two-year grace period.
Entity
Attach to a validly licensed contractor using the signed/notarized status-change request and fees.
Multiple Entities
At least thirty-percent common ownership is required to qualify multiple companies, except joint ventures.
New Certificate
A never-attached new QP has one-year score validity and must retain active six-month approval.

Official no-examination sources

Effective from 2026-09-22.

Qualifying party recertification — EE 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EE-98 — (a) EE-98. Residential, and commercial and industrial electrical wiring 5000 volts, nominal or less. Requires four years’ experience. Includes all electrical systems and wiring methods operating at 5000 volts, nominal, or less; electrical systems and wiring methods identified in electrical specialty classifications ES-1, ES-2, ES-3 and ES-7 ES-10R, or ES-10 residential electrical systems and wiring methods identified in classification ER-1; trenching and ductwork associated with classification EL-1; associated excavating, trenching, boring, shoring, backfilling, compacting for all electrical systems and wiring methods of 5000 volts, nominal or less. Does not include electrical wiring defined in the EL-1 classification other than trenching and duct work as specified above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the electrical NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — EL 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EL-1 — (c) EL-1. Electrical distribution and transmission systems over 5000 volts, nominal. Requires four years’ experience. Includes all electrical systems and wiring methods operating at over 5000 volts, nominal; overhead or underground electrical distribution and transmission circuits, equipment,; associated towers, tower foundations and other supporting structures; associated excavating, trenching, boring, shoring, backfilling, compacting and ductwork; sub-stations and terminal facilities. Does not include any electrical wiring specified or other electrical classifications EE-98, ER-1, ES-1, ES-2, ES-3, ES-7, ES-10R or ES-10. (2) Electrical Specialty licenses.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ER 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ER-1 — (b) ER-1. Residential electrical wiring 5000 volts, nominal or less. Requires two years’ experience. Includes electrical systems and wiring methods of 5000 volts, nominal or less at residential one and two-family dwelling units; multi-family dwellings when all such units are all on the ground floor with no occupancies above or below, as set forth in 14.10.4 NMAC. Does not include wiring for commercial use, such as motels, hotels and similar occupancies. May not contract for more than four dwelling units in any single building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ES 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-1 — (a) ES-1. Electrical signs and outline lighting. Requires two years’ experience. Installation at commercial locations only. Outline lighting is an arrangement of LED, incandescent lamps, or gaseous tubes to outline and call attention to certain features such as the shape of a building or the decoration of a window and may or may not contribute to the general illumination of an area. Includes commercial electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the sign or outline lighting where a “sign circuit” or outline lighting circuit has been provided within 10 feet of the roof or wall of the structure supporting the sign or outline lighting; concrete for the foundation of poles; build structures for the support of such signs associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the “sign circuit” not to exceed 10 feet from the foundation of the sign. 14.6.6 NMAC 6
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ES 10

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10 — (f) ES-10. Water well pump installer. Requires two years’ experience. Commercial water well pumps, 600 volts or less, single or three phase. Includes the installation, maintenance, repairing or replacing electrical equipment, wiring, and accessories directly associated with water well pump systems; variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation and trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment. Does not include systems over 600 volts, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ES 10R

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10R — (e) ES-10R. Residential water well pump installer. Requires two years’ experience. Residential water well pumps, 120/240 volts or less, single phase 15 HP or less. Includes the installation, maintenance, repairing or replacement of electrical equipment, wiring, and accessories directly associated with water well pump systems; single phase variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation, trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment; does not include electrical systems over 240 volts, pumps over 15 HP, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ES 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-2 — (b) ES-2. Cathodic protection and lightening protection systems. Requires two years’ experience. Includes interior and exterior cathodic protection and lightening protection systems at commercial and residential locations; electrical wiring methods of 5000 volts, nominal or less required to complete a cathodic grounding protection system only; electrical wiring methods of 5000 volts, nominal or less required to complete a lightening protection system only. May not install the service riser, main service or service grounding.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ES 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-3 — (c) ES-3. Low voltage special systems (under 50 volts). Requires two years’ experience. Interior and exterior special systems, cabling and interconnections at commercial and residential locations, privately and publically owned operating at 50 volts or less; includes telecommunications systems; fire alarm systems, CATV systems; audio and visual systems; security systems; door and gate operated control circuits; temperature control circuits, other low voltage specialty systems operating at 50 volts or less; low voltage special systems cables installed in plenum or non-plenum rated walls or ceilings; low voltage special systems cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial low voltage special systems cables; overhead low voltage special systems cabling to structures; terminations and splicing of low voltage special system conductors; associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods required to complete any of the special systems listed above. An installer of television receive-only (TVROs) (dishes) is not required to have a contractor’s license when the installation is in a single-family dwelling and does not require the use of 120 volts for tracking. Does not include interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 or ER-1 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — ES 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-7 — (d) ES-7. Telephone communication systems. Requires two years’ experience. Interior and exterior telecommunications cabling and interconnections at commercial and residential locations, in publicly or privately owned buildings; includes telecommunication cables installed in plenum or non-plenum rated walls or ceilings; telecommunication cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial telecommunication cables; overhead telecommunication cabling to structures; terminations and splicing of communication conductors; associated excavating trenching, boring, shoring, backfilling, compacting, installation of underground electrical wiring methods required to complete the installation of telecommunications systems; terminal facilities; installation of integrated services digital network cross connect equipment; installation of VoIP switching technology equipment, repeaters, including the installation of instruments at their terminating locations. Does not include Interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — EV 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EV-98 — EV-98 Elevators, Escalators, Conveyors. Requires four years of experience.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years of experience
Experience Alternatives
Four years (8,000 hours), or completion of NAEC CETT or the IUEC program with a mechanic’s card; those program credentials waive the experience affidavit, not the EV98 exam.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GA 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-1 — (1) GA-1. Streets, roads and highways, including tunnels, parking lots, alleys, seal coat and surfacing. Requires two years’ experience. Clear, align, fill, compress, compact, build up or remove earth and do all work necessary to prepare, within the assigned rights-of-way, the land to accept a streets, roads, highways including culverts and tunnels, and alleys; includes parking lots, sidewalks or driveways; place and finish concrete or bituminous materials and apply sealcoat. This classification includes the scopes of work authorized by GA-2 and GA-3.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GA 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-2 — (2) GA-2. Maintenance and repair. Requires two years’ experience. Fix, maintain, repair, patch, mend, cover, fill or replace with materials of like substances to that currently existing on streets, roads, highways, parking lots, driveways, sidewalks and alleys; apply seal coat to driveways and parking lots. Install rumble strips.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GA 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-3 — (3) GA-3. Curbs, gutters and driveway culverts. Requires two years’ experience. Form, place and finish concrete curbs, gutters, driveway culverts, public sidewalks and bituminous ridge curbs for the deflection of water.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GA 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-4 — (4) GA-4. Striping. Requires two years’ experience. Paint directional stripes on paved roads, streets, highways, alleys and parking lots; install auto parking bumpers or stops and highway lane markers/reflectors.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GA 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-5 — (5) GA-5. Highway signs and guard rails. Requires two years’ experience. Erect and stabilize signs and guard rails along public highways, streets, roads and alleys, which are used for the direction and safety of vehicular traffic. Electrical signs must be installed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GA 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-98 — (6) GA-98. Asphalt, bitumen and concrete construction. Indicates licensure in classifications GA-1 through GA-5; and covers all work authorized in those classifications. B. Residential and commercial building.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Four years under the May 2025 QP application for GA-98
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GB 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-2 — (1) GB-2. Residential. Requires two years’ of foreman level practical or related trade experience. Erect, alter, repair or demolish residences and apartment houses accommodating not more than four family units, Groups R-1, R-2 and R-3, as those groups are defined in 14.7.2 NMAC; items included in Group U, as defined in 14.7.2 NMAC, when incidental to these structures; includes all work described by the GS specialty classifications, provided the work is limited to residential construction as defined under this provision.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GB 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-98 — (2) GB-98. General building. Requires four years of foreman level practical or related trade experience of which at two years must be commercial experience. Erect, alter, repair or demolish residential and commercial buildings, and certain structures; includes all work authorized by the GB-2, GF-5, GF-7 and GS classifications; seal coating and striping of driveways and parking lots; excludes those structures covered by the EE, MM, GA or GF classifications. C. Fixed works. Construct, alter or repair fixed or public works facilities; provided, however, that work in any trade or craft that is authorized by any one, or a combination of, the mechanical, electrical, or general building or LP Gas classifications must be performed by an entity validly licensed in the appropriate classification. Except as may be expressly provided in a specific classification description, fixed works licensees may not construct buildings that are primarily for the use and occupancy of the general public, but may bid and contract for such buildings when they are incidental to a fixed works project; however, such work must be subcontracted pursuant to Subsection B of 14.6.6.8 NMAC, above. Incidental storage buildings used exclusively for storage and not for occupancy are allowed within these classifications. 14.6.6 NMAC 2
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Four years of foreman-level practical or related trade experience, including two years of commercial experience.
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the general construction NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-1 — (1) GF-1. Airports. Requires two years’ experience. Construct, alter and repair airports, including excavating, grading, compacting, sub-surfacing, surfacing (dirt or bitumen and concrete), marking and other work on surfaces to be used for aircraft traffic, landing, take-off and taxi.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-2 — (2) GF-2. Bridges. Requires two years’ experience. Erect, construct, alter, repair or demolish any bridge, overpass or underpass, culvert or ramp, generally used for vehicular traffic.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-3 — (3) GF-3. Canals, reservoirs, dams and irrigation systems. Requires two years’ experience. Construct, erect, alter, repair, or demolish canals, dams, reservoirs irrigation systems; excavate, ditch, fill, compact and place pre-cast components, waterproof membranes and liners, concrete reinforcement, abutments and buttresses in connection therewith; install tanks, pumps, pipelines and substations incidental to the project; irrigation activities and piping when applicable solely to the production of agriculture or maintenance of livestock on a farm or ranch, excluding electrical work, are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-4 — (4) GF-4. Drainage or flood control systems. Requires two years’ experience. Construct, erect, install, repair and alter drainage or flood control systems; dig, excavate, fill, prepare embankments for such purposes, place pre-cast components, concrete reinforcement and perform all other work incidental to these projects.; install storm sewers, including trenching, boring, shoring, backfilling, compacting, and paving.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-5 — (5) GF-5. Recreation areas. Requires two years’ experience. Construct, prepare, clear, repair or alter facilities for use as recreation areas, including but not limited to golf courses, driving ranges, water parks, tennis courts, playgrounds, outdoor athletic facilities, miniature golf courses, pitch-and-putt golf courses; prepare the area by excavation, fill, including foundations, retaining walls, sprinkler systems, rest benches, shade and rain shelters and foot bridges relative to recreation areas; public campgrounds and parks or similar facilities, including toilet facilities and lean-tos.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-6 — (6) GF-6. Railroad and tunnel construction. Requires two years’ experience. Construct railroad lines, including clearing, filling, shaping, compacting, placing rip-rap, stabilizing, setting roadbeds, ties, tie plates, rails, rail connectors, frogs, switch plates, switches, and all appurtenances necessary for an operational railroad line, including bridges, culverts, tunnels, retaining walls, dikes, gates, tool sheds and landing or parking platforms for equipment. Includes welding operations necessary for rail construction.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-7 — (7) GF-7. Tanks and towers. Requires two years’ experience. Construct or fabricate on site and install tanks for the storage of solids or liquids, above or below ground, and towers such as radio, television and telecommunications towers, including all necessary site-work, excavation and construction of concrete tanks, pads and foundations, cutting, welding, placement of structural members, engineered structural support systems for elevated tanks, and engineered or prefabricated towers; includes the repair and placement of liners in tanks, and incidental storage buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-8 — (8) GF-8. Transmission lines, tanks and substations (non-electrical). Requires two years’ experience. Build, construct and place lines for the transmission or conveyance of natural gas or petroleum, water and other fluid substances, including the application of protective coatings, trenching, boring, shoring, backfilling, compacting, paving and surfacing necessary and incidental to the completion of the installation of such facilities. Includes incidental buildings, tanks, and substations required for the project; construct, alter or repair industrial plants, including, but not limited to, refineries and power generation plants.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-9 — (9) GF-9. Utility lines and systems (sewage, water, natural gas and underground telephone cables). Requires two years’ experience. Construct, install, alter or repair utility lines and utility systems for the transmission of sewage, natural gas and water, including excavating, grading, trenching, boring, shoring, backfilling, compacting, paving and surfacing; includes tanks, pumps, lift-stations and substations incidental to the project; construct, alter, or repair treatment plants and facilities incidental thereto; install direct burial communications cable by trenching, direct plowing or pulling direct burial cable through existing raceways and install vaults as directed by the telecommunications utility; associated excavating, trenching, boring, shoring, backfilling, compacting, paving and surfacing. Shall not perform installation of electrical raceways including directional boring or pipe jacking methods, splicing, termination, installation of load pots, installation of integrated services digital network cross connect equipment, installation of VoIP switching technology equipment, overhead cabling work, or other activities considered under the scope of the ES-7, EL-1, ES-3 or EE-98 electrical classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GF 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-98 — (10) GF-98. Construct, alter or repair fixed works facilities. Requires four years’ experience; indicates licensure in classifications GF-1 through GF-9 and authorizes all work described in these classifications. D. General Specialty classifications. General construction includes numerous specialties. Therefore, CID has established the GS classification series to enable entities that perform this kind of work to be 14.6.6 NMAC 3
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 1
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-1 — (1) GS-1. Acoustical insulation and insulation. Requires two years’ experience. Install any insulating material, including urethane foam and approved waterproof membranes and coatings, in or on buildings, structures and on piping for the purpose of energy conservation, temperature and sound control, and fireproofing. Does not include the installation of urethane roof systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 13

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-13 — (8) GS-13. Framing. Requires two years of foreman level practical or related trade experience; cut, join, install wood, metal or other products approved by the division and utilized for the framing of a structure or building, including bearing and non-bearing walls, rafters, headers, trusses, joists, studs, door and window rough frames, and roof decks, including repair to any of the above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 14
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-14 — (9) GS-14. Windows, doors and skylights. Requires two years’ experience. Fabricate and install windows and doors in buildings and structures, including the necessary installation of window, door and skylight framing, and the installation of necessary hardware; cut, assemble and install glass work, and execute the glazing of frames, panels, sash and doors; fabricate and install storm doors, windows, and skylights including flashing; does not include structural alterations to enlarge any opening.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Vendor Door Exam
The April 2026 PSI bulletin names GS-6 Door Installation, whereas the March 2022 codified classification is GS-14 Windows, doors and skylights. Neither source explicitly assigns the GS-6 paper to GS-14; that association is undetermined and is not inferred from topic overlap.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 15
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-15 — (10) GS-15. Caissons, piers and pile driving. Requires two years’ experience. Install piers, caissons and pilings through the use of pile driving equipment and machinery, including necessary excavation, grading and clearing for site preparation for pile driving activities; cut, weld, join and fabricate caissons or piles; install all necessary concrete and reinforcing steel within the caissons to create a structural member; soil stabilization and rock-fall mitigation.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 16

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-16 — (11) GS-16. Masonry. Requires two years’ experience. Install or erect brick and other baked clay products, rough cut and dressed stone, artificial stone and pre-cast blocks, structural glass brick or block adobe, laid at random or in courses, with or without mortar, to form masonry walls, anchored stone or masonry veneer, including building walls, freestanding walls six feet or higher from ground level and retaining walls measuring thirty-six inches or more measured from the bottom of the footing; does not include the execution, fabrication and erecting of poured cement and concrete, except as a foundation for a wall. 14.6.6 NMAC 4
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 2
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-2 — (2) GS-2. Awnings and canopies. Requires two years’ experience. Construct, erect and install awnings and canopies, attached to buildings and structures or free standing, including, but not limited to carports and service station canopies, and including necessary excavation and foundation work. All electrical work shall be performed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 21

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-21 — (12) GS-21. Roofing. Requires two years of foreman level practical or related trade experience. Install, alter or repair roof systems on new or existing roof decks to create a weatherproof and waterproof protective membrane, with or without insulation, using asphalt, pitch, tar, sealants, felt, shakes, shingles, roof tile, slate, urethane or any other approved materials including the preparatory work necessary to bring a roof deck or an existing roof to a condition where roofing can be installed, and sealed or repaired; includes cutting, shaping, fabricating, and installing of sheet metal such as cornices, flashing, skylights (excluding alterations to structural framing), roof coatings, gutters, leaders, rainwater downspouts, pans, prefabricated chimneys, at or near roof lines, metal flues, or doing any part of any combination thereof, which relate to and are incidental to roofing projects.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 23
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-23 — (13) GS-23. Sign construction (non-electrical). Requires two years’ experience. Fabricate on site, install and erect signs of wood, steel, plastic or any material, or any combination of materials, which are to be embedded in the earth, in concrete or other base material, or attached to buildings or structures using anchors, attached cables, bars or similar devices and appurtenances; electrified signs shall only be installed by contractors holding an ES-1 or an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 24

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-24 — (14) GS-24. Structural steel erection. Requires two years of foreman level practical or related trade experience. Fabricate on site and erect structural steel shapes and plates, of any profile, perimeter or cross-section that may be used as structural members for buildings and structures, including riveting and welding; does not authorize construction of concrete foundations or complete buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 25

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-25 — (15) GS-25. Swimming pools (non-plumbing, mechanical or electrical). Requires two years’ experience. Construct and repair swimming pools including excavation, installation of reinforcing steel or mesh, application of concrete and special coatings; shall not perform any scope of work which is authorized by a plumbing, mechanical, electrical or LP Gas classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 29
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-29 — (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
up to four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 30

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-30 — (16) GS-30. Plastering, stucco and lathing. Requires two years’ experience. Prepare wall and ceiling surfaces, interior or exterior, with wood, metal lath, wallboard or other properly prepared surfaces which will accept and hold a mixture of sand, plaster (including gypsum plaster), lime and water, or sand and cement with water or any combination of materials to create a permanent surface coating; these coatings may be applied manually or mechanically on surfaces which will support such coating; install steel or wood or other division approved stud systems (non-structural), channel iron work and affix lath or any other materials or products, prepared or manufactured to provide a base for such coatings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 31
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-31 — (17) GS-31. Siding. Requires two years’ experience. Apply, replace, or repair siding consisting of slate, gypsum, wood, plastics or other products, including the application of furred up networks on which the siding can be installed.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 32
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-32 — (18) GS-32. Miscellaneous sheet metal. Requires two years’ experience. Fabricate on site and install sheet metal (galvanized iron) such as cornices, flashing, gutters, leaders, rainwater downspouts, pans, and prefabricated chimneys; shall not install heating, ventilation & air conditioning (HVAC) duct systems, vents, grease hoods, or other appurtenances that are authorized by mechanical or plumbing classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 34
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-34 — (19) GS-34. Concrete coring, drilling and slab sawing. Requires two years’ experience. Coring, boring, drilling, cutting, and sawing concrete, including the removal or demolition of the material; does not include the installation of electrical wiring or plumbing in such bored, drilled, cut or sawed concrete. (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis. [14.6.6.9 NMAC - Rp, 14.6.6.9 NMAC, 3/10/2022]
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-4 — (3) GS-4. Concrete, cement, walkways and driveways. Requires two years’ experience practical trade experience, one year of which must be foreman level. Mix, pour, place, and finish concrete,; includes all necessary preparatory work including excavation, form work, and placing of reinforcement materials; includes the installation on private property of curbs, gutters, sidewalks, and driveway culverts; may not perform this work in public rights-of-way unless subcontracted to a validly licensed GA licensee.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
Two years of practical trade experience, including one year at foreman level.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 5
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-5 — (4) GS-5. Demolition. Requires two years’ experience. Demolish all or any portion of a buildings and structures authorized by the GB-98 classification, including demolition to portions of buildings and structures allowing additions and alterations to be completed to the remaining portions of the building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-7 — (5) GS-7. Drywall installation and texture. Requires two years’ experience. Installation of gypsum wallboard, and gypsum sheathing; includes taping, bedding and coating the surfaces of the wallboard and sheathing with gypsum joint systems, tape and drywall mud, or a combination of other materials to create a permanent surface or coating and of walls and ceilings; install steel or wood stud systems (non-structural) and channel iron work to provide a base for the application of drywall.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-8 — (6) GS-8. Earthmoving, excavating and ditching. Requires two years’ experience. Perform earthwork associated with or incidental to construction projects regulated by CID, using hand or power tools, machines that use air, fluids, or other material under pressure, or heavy equipment, in such a manner that cutting, filling, excavating, grading, trenching, backfilling, boring and any similar excavating activity can be executed; earthmoving, excavating and ditching activities applicable to the preparation and production of agriculture or maintenance of livestock on a farm or ranch are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — GS 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-9 — (7) GS-9. Elevators, escalators, and related machinery (non-electrical). Requires two years’ experience. Erect, install or repair elevators, escalators and related machinery, including sheave beams, sheaves, cable and wire rope, guides, cab, counterweights, doors, including sidewalk elevators, automatic and manual controls, signal systems and all other devices, apparatus, machinery and equipment (including fabrication on job site) essential to the safe and efficient installation and operation of electrical, hydraulic and manually operated elevators and escalators and conveyors designed specifically for the transportation of people.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MM 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-1 — (1) MM-1. Plumbing. Requires four years’ experience. Install, alter, repair, service, and maintain plumbing, plumbing fixtures, and piping, includes incidental concrete supports, and excavating, trenching and backfilling; includes hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; piping for fuel, oil and gasoline; piping and appurtenances for solar thermal energy systems; potable water irrigation sprinkler systems; swimming pools and spas; includes pneumatic or electric controls and control wiring not greater than 24 volts; septic tanks, manholes and sewer lines; does not include installation of natural gas fired appliances or natural gas piping; piping and agricultural sprinkler irrigation system installation and maintenance on farm or ranch property that moves water for livestock use or irrigation purposes from a privately owned well or pipeline, not connected to a public potable water supply are exempt from licensing requirements. When connected to a potable water source all connections must be downstream of an approved back flow prevention device. If a backflow prevention device is required it shall be permitted and installed by a properly certified journeyman employed by an appropriately licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MM 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-2 — (2) MM-2. Natural gas fitting. Requires four years’ experience. Install, alter, repair, service and maintain natural gas piping and fittings; install hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; steam and hot water boilers; may connect water to existing valved outlets; warm air heating systems including chimney connections, flues, refractories, burners, fittings valves, thermal insulation, accessories and incidental piping; warm air appliances and other listed gas appliances; incidental controls and control wiring, pneumatic control systems; includes all required excavating, trenching and backfilling. May not install LP Gas systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MM 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-3 — (3) MM-3. Heating, ventilation & air conditioning (HVAC). Requires four years’ experience. Install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping, including fans, coils, condensing units, self-contained packaged air conditioning or heating units, evaporative cooling units, and ductwork and accessories including solar air heating and cooled mechanical air handling and 14.6.6 NMAC 8
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MM 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-4 — (4) MM-4. Heating, cooling and process piping. Requires four years’ experience. Install, alter, repair, service and maintain hydronic heating, cooling and process piping, piping and appurtenances for steam and hot water systems of any temperature or pressure range, chilled water systems, condensing water systems and other process piping systems; includes air handling equipment, pressure vessels, heat exchangers, boilers, refrigeration water chillers, cooling towers, fuel oil tanks and fuel oil piping; electric controls and control wiring not to exceed 24 volts; install high pressure and process piping solar thermal energy systems of any temperature or pressure range conveying gas or fluids other than potable water; water based fire protection sprinkler systems, dry chemical fire protection systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MM 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-98 — (5) MM-98. Mechanical. Requires four years’ experience. Indicates licensure in individual classifications MM-1 through MM-4 and covers all work described in these classifications, as well as work described in the MS-3, MS-6, MS-12 and MS-14. C. Mechanical Specialty classifications:
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MS 12

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-12 — (3) MS-12. Fire protection sprinkler systems. Requires four years’ experience. Install alter, repair, service or maintain water-based fire protection systems required pressure or storage tanks, controls and control wiring up to 24 volts; excavate and backfill and install piping from structure to off-site water supply adjacent to fire protection system property; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a validly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MS 14

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-14 — (4) MS-14. Dry chemical fire protection. Requires four years’ experience. Install, alter, repair, or service or maintain gaseous or chemical based fire protection systems including carbon dioxide (CO), or clean agents; pressurized storage tanks, valves, temperature sensing devices, solenoid or safety shut-off devices and other incidental controls and control wiring up to 24 volts; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a properly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MS 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-3 — (1) MS-3. Septic tanks & sewer. Requires two years’ experience. Install, alter, repair, service or maintain septic tanks and private sewage disposal systems, manholes and sewer lines, beginning at a connection to a public or private utility and ending at a point five feet beyond the outside wall of a building or structured; excavate, trench, backfill and grade as necessary; install or repair incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.
Qualifying party recertification — MS 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-6 — (2) MS-6. Lawn sprinklers. Requires two years’ experience. Install, alter, repair, service or maintain potable water sprinkler systems; excavate, trench, backfill and grade as necessary; backflow prevention devices incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Director Waiver
Director may waive the retest for an additional twelve months on documented work experience showing equivalent technical and business knowledge.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Prior Certificate
Certificate expired after two consecutive years without qualifying a valid license, or a new qualifying-party certificate is required following revocation.
Score Validity
Passing examination scores are valid for one year.
Work Recency
Required practical/trade experience must be within the ten years before application.

Temporary Certificate of Qualification

Temporary replacement qualifying-party certificate for an experienced employee after loss of the regular qualifying party; regular examinations must be passed within ninety days.

Licensing authority: New Mexico Regulation and Licensing Department, Construction Industries Division · Application information

Temporary replacement qualifying party — EE 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EE-98 — (a) EE-98. Residential, and commercial and industrial electrical wiring 5000 volts, nominal or less. Requires four years’ experience. Includes all electrical systems and wiring methods operating at 5000 volts, nominal, or less; electrical systems and wiring methods identified in electrical specialty classifications ES-1, ES-2, ES-3 and ES-7 ES-10R, or ES-10 residential electrical systems and wiring methods identified in classification ER-1; trenching and ductwork associated with classification EL-1; associated excavating, trenching, boring, shoring, backfilling, compacting for all electrical systems and wiring methods of 5000 volts, nominal or less. Does not include electrical wiring defined in the EL-1 classification other than trenching and duct work as specified above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the electrical NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — EL 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EL-1 — (c) EL-1. Electrical distribution and transmission systems over 5000 volts, nominal. Requires four years’ experience. Includes all electrical systems and wiring methods operating at over 5000 volts, nominal; overhead or underground electrical distribution and transmission circuits, equipment,; associated towers, tower foundations and other supporting structures; associated excavating, trenching, boring, shoring, backfilling, compacting and ductwork; sub-stations and terminal facilities. Does not include any electrical wiring specified or other electrical classifications EE-98, ER-1, ES-1, ES-2, ES-3, ES-7, ES-10R or ES-10. (2) Electrical Specialty licenses.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ER 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ER-1 — (b) ER-1. Residential electrical wiring 5000 volts, nominal or less. Requires two years’ experience. Includes electrical systems and wiring methods of 5000 volts, nominal or less at residential one and two-family dwelling units; multi-family dwellings when all such units are all on the ground floor with no occupancies above or below, as set forth in 14.10.4 NMAC. Does not include wiring for commercial use, such as motels, hotels and similar occupancies. May not contract for more than four dwelling units in any single building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ES 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-1 — (a) ES-1. Electrical signs and outline lighting. Requires two years’ experience. Installation at commercial locations only. Outline lighting is an arrangement of LED, incandescent lamps, or gaseous tubes to outline and call attention to certain features such as the shape of a building or the decoration of a window and may or may not contribute to the general illumination of an area. Includes commercial electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the sign or outline lighting where a “sign circuit” or outline lighting circuit has been provided within 10 feet of the roof or wall of the structure supporting the sign or outline lighting; concrete for the foundation of poles; build structures for the support of such signs associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods of 5000 volts, nominal or less required to complete the installation of the “sign circuit” not to exceed 10 feet from the foundation of the sign. 14.6.6 NMAC 6
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ES 10

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10 — (f) ES-10. Water well pump installer. Requires two years’ experience. Commercial water well pumps, 600 volts or less, single or three phase. Includes the installation, maintenance, repairing or replacing electrical equipment, wiring, and accessories directly associated with water well pump systems; variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation and trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment. Does not include systems over 600 volts, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ES 10R

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-10R — (e) ES-10R. Residential water well pump installer. Requires two years’ experience. Residential water well pumps, 120/240 volts or less, single phase 15 HP or less. Includes the installation, maintenance, repairing or replacement of electrical equipment, wiring, and accessories directly associated with water well pump systems; single phase variable frequency drives; subpanels, luminaires, and receptacle outlets installed within the well pit or well enclosure; branch circuit or feeder conductors from the service equipment or panel board to the well pump location; incidental excavation, trenching; solar photo-voltaic arrays 5 kW or less when dedicated to pumping equipment; does not include electrical systems over 240 volts, pumps over 15 HP, electrical services, building wiring or any other electrical wiring.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ES 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-2 — (b) ES-2. Cathodic protection and lightening protection systems. Requires two years’ experience. Includes interior and exterior cathodic protection and lightening protection systems at commercial and residential locations; electrical wiring methods of 5000 volts, nominal or less required to complete a cathodic grounding protection system only; electrical wiring methods of 5000 volts, nominal or less required to complete a lightening protection system only. May not install the service riser, main service or service grounding.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ES 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-3 — (c) ES-3. Low voltage special systems (under 50 volts). Requires two years’ experience. Interior and exterior special systems, cabling and interconnections at commercial and residential locations, privately and publically owned operating at 50 volts or less; includes telecommunications systems; fire alarm systems, CATV systems; audio and visual systems; security systems; door and gate operated control circuits; temperature control circuits, other low voltage specialty systems operating at 50 volts or less; low voltage special systems cables installed in plenum or non-plenum rated walls or ceilings; low voltage special systems cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial low voltage special systems cables; overhead low voltage special systems cabling to structures; terminations and splicing of low voltage special system conductors; associated excavating, trenching, boring, shoring, backfilling, compacting; installation of underground electrical wiring methods required to complete any of the special systems listed above. An installer of television receive-only (TVROs) (dishes) is not required to have a contractor’s license when the installation is in a single-family dwelling and does not require the use of 120 volts for tracking. Does not include interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 or ER-1 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — ES 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
ES-7 — (d) ES-7. Telephone communication systems. Requires two years’ experience. Interior and exterior telecommunications cabling and interconnections at commercial and residential locations, in publicly or privately owned buildings; includes telecommunication cables installed in plenum or non-plenum rated walls or ceilings; telecommunication cables in existing raceways installed by others as defined at Paragraph (2) of Subsection A of 14.6.6.10 NMAC; direct burial telecommunication cables; overhead telecommunication cabling to structures; terminations and splicing of communication conductors; associated excavating trenching, boring, shoring, backfilling, compacting, installation of underground electrical wiring methods required to complete the installation of telecommunications systems; terminal facilities; installation of integrated services digital network cross connect equipment; installation of VoIP switching technology equipment, repeaters, including the installation of instruments at their terminating locations. Does not include Interior or exterior wiring of circuits operating above 50 volts which requires an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — EV 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
EV-98 — EV-98 Elevators, Escalators, Conveyors. Requires four years of experience.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years of experience
Experience Alternatives
Four years (8,000 hours), or completion of NAEC CETT or the IUEC program with a mechanic’s card; those program credentials waive the experience affidavit, not the EV98 exam.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GA 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-1 — (1) GA-1. Streets, roads and highways, including tunnels, parking lots, alleys, seal coat and surfacing. Requires two years’ experience. Clear, align, fill, compress, compact, build up or remove earth and do all work necessary to prepare, within the assigned rights-of-way, the land to accept a streets, roads, highways including culverts and tunnels, and alleys; includes parking lots, sidewalks or driveways; place and finish concrete or bituminous materials and apply sealcoat. This classification includes the scopes of work authorized by GA-2 and GA-3.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GA 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-2 — (2) GA-2. Maintenance and repair. Requires two years’ experience. Fix, maintain, repair, patch, mend, cover, fill or replace with materials of like substances to that currently existing on streets, roads, highways, parking lots, driveways, sidewalks and alleys; apply seal coat to driveways and parking lots. Install rumble strips.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GA 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-3 — (3) GA-3. Curbs, gutters and driveway culverts. Requires two years’ experience. Form, place and finish concrete curbs, gutters, driveway culverts, public sidewalks and bituminous ridge curbs for the deflection of water.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GA 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-4 — (4) GA-4. Striping. Requires two years’ experience. Paint directional stripes on paved roads, streets, highways, alleys and parking lots; install auto parking bumpers or stops and highway lane markers/reflectors.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GA 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-5 — (5) GA-5. Highway signs and guard rails. Requires two years’ experience. Erect and stabilize signs and guard rails along public highways, streets, roads and alleys, which are used for the direction and safety of vehicular traffic. Electrical signs must be installed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GA 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GA-98 — (6) GA-98. Asphalt, bitumen and concrete construction. Indicates licensure in classifications GA-1 through GA-5; and covers all work authorized in those classifications. B. Residential and commercial building.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
Four years under the May 2025 QP application for GA-98
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GB 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-2 — (1) GB-2. Residential. Requires two years’ of foreman level practical or related trade experience. Erect, alter, repair or demolish residences and apartment houses accommodating not more than four family units, Groups R-1, R-2 and R-3, as those groups are defined in 14.7.2 NMAC; items included in Group U, as defined in 14.7.2 NMAC, when incidental to these structures; includes all work described by the GS specialty classifications, provided the work is limited to residential construction as defined under this provision.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GB 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GB-98 — (2) GB-98. General building. Requires four years of foreman level practical or related trade experience of which at two years must be commercial experience. Erect, alter, repair or demolish residential and commercial buildings, and certain structures; includes all work authorized by the GB-2, GF-5, GF-7 and GS classifications; seal coating and striping of driveways and parking lots; excludes those structures covered by the EE, MM, GA or GF classifications. C. Fixed works. Construct, alter or repair fixed or public works facilities; provided, however, that work in any trade or craft that is authorized by any one, or a combination of, the mechanical, electrical, or general building or LP Gas classifications must be performed by an entity validly licensed in the appropriate classification. Except as may be expressly provided in a specific classification description, fixed works licensees may not construct buildings that are primarily for the use and occupancy of the general public, but may bid and contract for such buildings when they are incidental to a fixed works project; however, such work must be subcontracted pursuant to Subsection B of 14.6.6.8 NMAC, above. Incidental storage buildings used exclusively for storage and not for occupancy are allowed within these classifications. 14.6.6 NMAC 2
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
Four years of foreman-level practical or related trade experience, including two years of commercial experience.
Minimum Age
At least eighteen years old.
Nascla Waiver
May 2025 QP instructions: waiver for GB98 and EE98 only; use NASCLA scores to obtain another-jurisdiction license, hold that license at least one year, release the NASCLA transcript, and receive CID approval. The waiver removes only the trade test; experience and business-law requirements remain.
Nationwide Accredited Exam
The state accepts the general construction NASCLA accredited examination for a discretionary trade-examination waiver under 14.6.3.8(G)(2)(f). No corresponding nationwide version was supplied in sharedExamContext or knownRegistrations; this accepted examination is retained as an applicant condition pending nationwide registration.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-1 — (1) GF-1. Airports. Requires two years’ experience. Construct, alter and repair airports, including excavating, grading, compacting, sub-surfacing, surfacing (dirt or bitumen and concrete), marking and other work on surfaces to be used for aircraft traffic, landing, take-off and taxi.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-2 — (2) GF-2. Bridges. Requires two years’ experience. Erect, construct, alter, repair or demolish any bridge, overpass or underpass, culvert or ramp, generally used for vehicular traffic.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-3 — (3) GF-3. Canals, reservoirs, dams and irrigation systems. Requires two years’ experience. Construct, erect, alter, repair, or demolish canals, dams, reservoirs irrigation systems; excavate, ditch, fill, compact and place pre-cast components, waterproof membranes and liners, concrete reinforcement, abutments and buttresses in connection therewith; install tanks, pumps, pipelines and substations incidental to the project; irrigation activities and piping when applicable solely to the production of agriculture or maintenance of livestock on a farm or ranch, excluding electrical work, are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-4 — (4) GF-4. Drainage or flood control systems. Requires two years’ experience. Construct, erect, install, repair and alter drainage or flood control systems; dig, excavate, fill, prepare embankments for such purposes, place pre-cast components, concrete reinforcement and perform all other work incidental to these projects.; install storm sewers, including trenching, boring, shoring, backfilling, compacting, and paving.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 5

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-5 — (5) GF-5. Recreation areas. Requires two years’ experience. Construct, prepare, clear, repair or alter facilities for use as recreation areas, including but not limited to golf courses, driving ranges, water parks, tennis courts, playgrounds, outdoor athletic facilities, miniature golf courses, pitch-and-putt golf courses; prepare the area by excavation, fill, including foundations, retaining walls, sprinkler systems, rest benches, shade and rain shelters and foot bridges relative to recreation areas; public campgrounds and parks or similar facilities, including toilet facilities and lean-tos.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-6 — (6) GF-6. Railroad and tunnel construction. Requires two years’ experience. Construct railroad lines, including clearing, filling, shaping, compacting, placing rip-rap, stabilizing, setting roadbeds, ties, tie plates, rails, rail connectors, frogs, switch plates, switches, and all appurtenances necessary for an operational railroad line, including bridges, culverts, tunnels, retaining walls, dikes, gates, tool sheds and landing or parking platforms for equipment. Includes welding operations necessary for rail construction.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-7 — (7) GF-7. Tanks and towers. Requires two years’ experience. Construct or fabricate on site and install tanks for the storage of solids or liquids, above or below ground, and towers such as radio, television and telecommunications towers, including all necessary site-work, excavation and construction of concrete tanks, pads and foundations, cutting, welding, placement of structural members, engineered structural support systems for elevated tanks, and engineered or prefabricated towers; includes the repair and placement of liners in tanks, and incidental storage buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-8 — (8) GF-8. Transmission lines, tanks and substations (non-electrical). Requires two years’ experience. Build, construct and place lines for the transmission or conveyance of natural gas or petroleum, water and other fluid substances, including the application of protective coatings, trenching, boring, shoring, backfilling, compacting, paving and surfacing necessary and incidental to the completion of the installation of such facilities. Includes incidental buildings, tanks, and substations required for the project; construct, alter or repair industrial plants, including, but not limited to, refineries and power generation plants.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-9 — (9) GF-9. Utility lines and systems (sewage, water, natural gas and underground telephone cables). Requires two years’ experience. Construct, install, alter or repair utility lines and utility systems for the transmission of sewage, natural gas and water, including excavating, grading, trenching, boring, shoring, backfilling, compacting, paving and surfacing; includes tanks, pumps, lift-stations and substations incidental to the project; construct, alter, or repair treatment plants and facilities incidental thereto; install direct burial communications cable by trenching, direct plowing or pulling direct burial cable through existing raceways and install vaults as directed by the telecommunications utility; associated excavating, trenching, boring, shoring, backfilling, compacting, paving and surfacing. Shall not perform installation of electrical raceways including directional boring or pipe jacking methods, splicing, termination, installation of load pots, installation of integrated services digital network cross connect equipment, installation of VoIP switching technology equipment, overhead cabling work, or other activities considered under the scope of the ES-7, EL-1, ES-3 or EE-98 electrical classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GF 98

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GF-98 — (10) GF-98. Construct, alter or repair fixed works facilities. Requires four years’ experience; indicates licensure in classifications GF-1 through GF-9 and authorizes all work described in these classifications. D. General Specialty classifications. General construction includes numerous specialties. Therefore, CID has established the GS classification series to enable entities that perform this kind of work to be 14.6.6 NMAC 3
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 1
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-1 — (1) GS-1. Acoustical insulation and insulation. Requires two years’ experience. Install any insulating material, including urethane foam and approved waterproof membranes and coatings, in or on buildings, structures and on piping for the purpose of energy conservation, temperature and sound control, and fireproofing. Does not include the installation of urethane roof systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 13

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-13 — (8) GS-13. Framing. Requires two years of foreman level practical or related trade experience; cut, join, install wood, metal or other products approved by the division and utilized for the framing of a structure or building, including bearing and non-bearing walls, rafters, headers, trusses, joists, studs, door and window rough frames, and roof decks, including repair to any of the above.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 14
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-14 — (9) GS-14. Windows, doors and skylights. Requires two years’ experience. Fabricate and install windows and doors in buildings and structures, including the necessary installation of window, door and skylight framing, and the installation of necessary hardware; cut, assemble and install glass work, and execute the glazing of frames, panels, sash and doors; fabricate and install storm doors, windows, and skylights including flashing; does not include structural alterations to enlarge any opening.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Vendor Door Exam
The April 2026 PSI bulletin names GS-6 Door Installation, whereas the March 2022 codified classification is GS-14 Windows, doors and skylights. Neither source explicitly assigns the GS-6 paper to GS-14; that association is undetermined and is not inferred from topic overlap.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 15
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-15 — (10) GS-15. Caissons, piers and pile driving. Requires two years’ experience. Install piers, caissons and pilings through the use of pile driving equipment and machinery, including necessary excavation, grading and clearing for site preparation for pile driving activities; cut, weld, join and fabricate caissons or piles; install all necessary concrete and reinforcing steel within the caissons to create a structural member; soil stabilization and rock-fall mitigation.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 16

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-16 — (11) GS-16. Masonry. Requires two years’ experience. Install or erect brick and other baked clay products, rough cut and dressed stone, artificial stone and pre-cast blocks, structural glass brick or block adobe, laid at random or in courses, with or without mortar, to form masonry walls, anchored stone or masonry veneer, including building walls, freestanding walls six feet or higher from ground level and retaining walls measuring thirty-six inches or more measured from the bottom of the footing; does not include the execution, fabrication and erecting of poured cement and concrete, except as a foundation for a wall. 14.6.6 NMAC 4
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 2
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-2 — (2) GS-2. Awnings and canopies. Requires two years’ experience. Construct, erect and install awnings and canopies, attached to buildings and structures or free standing, including, but not limited to carports and service station canopies, and including necessary excavation and foundation work. All electrical work shall be performed by a properly licensed electrical contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 21

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-21 — (12) GS-21. Roofing. Requires two years of foreman level practical or related trade experience. Install, alter or repair roof systems on new or existing roof decks to create a weatherproof and waterproof protective membrane, with or without insulation, using asphalt, pitch, tar, sealants, felt, shakes, shingles, roof tile, slate, urethane or any other approved materials including the preparatory work necessary to bring a roof deck or an existing roof to a condition where roofing can be installed, and sealed or repaired; includes cutting, shaping, fabricating, and installing of sheet metal such as cornices, flashing, skylights (excluding alterations to structural framing), roof coatings, gutters, leaders, rainwater downspouts, pans, prefabricated chimneys, at or near roof lines, metal flues, or doing any part of any combination thereof, which relate to and are incidental to roofing projects.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 23
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-23 — (13) GS-23. Sign construction (non-electrical). Requires two years’ experience. Fabricate on site, install and erect signs of wood, steel, plastic or any material, or any combination of materials, which are to be embedded in the earth, in concrete or other base material, or attached to buildings or structures using anchors, attached cables, bars or similar devices and appurtenances; electrified signs shall only be installed by contractors holding an ES-1 or an EE-98 classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 24

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-24 — (14) GS-24. Structural steel erection. Requires two years of foreman level practical or related trade experience. Fabricate on site and erect structural steel shapes and plates, of any profile, perimeter or cross-section that may be used as structural members for buildings and structures, including riveting and welding; does not authorize construction of concrete foundations or complete buildings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years of foreman level practical or related trade experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 25

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-25 — (15) GS-25. Swimming pools (non-plumbing, mechanical or electrical). Requires two years’ experience. Construct and repair swimming pools including excavation, installation of reinforcing steel or mesh, application of concrete and special coatings; shall not perform any scope of work which is authorized by a plumbing, mechanical, electrical or LP Gas classification.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 29
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-29 — (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
up to four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 30

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-30 — (16) GS-30. Plastering, stucco and lathing. Requires two years’ experience. Prepare wall and ceiling surfaces, interior or exterior, with wood, metal lath, wallboard or other properly prepared surfaces which will accept and hold a mixture of sand, plaster (including gypsum plaster), lime and water, or sand and cement with water or any combination of materials to create a permanent surface coating; these coatings may be applied manually or mechanically on surfaces which will support such coating; install steel or wood or other division approved stud systems (non-structural), channel iron work and affix lath or any other materials or products, prepared or manufactured to provide a base for such coatings.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 31
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-31 — (17) GS-31. Siding. Requires two years’ experience. Apply, replace, or repair siding consisting of slate, gypsum, wood, plastics or other products, including the application of furred up networks on which the siding can be installed.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 32
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-32 — (18) GS-32. Miscellaneous sheet metal. Requires two years’ experience. Fabricate on site and install sheet metal (galvanized iron) such as cornices, flashing, gutters, leaders, rainwater downspouts, pans, and prefabricated chimneys; shall not install heating, ventilation & air conditioning (HVAC) duct systems, vents, grease hoods, or other appurtenances that are authorized by mechanical or plumbing classifications.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 34
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-34 — (19) GS-34. Concrete coring, drilling and slab sawing. Requires two years’ experience. Coring, boring, drilling, cutting, and sawing concrete, including the removal or demolition of the material; does not include the installation of electrical wiring or plumbing in such bored, drilled, cut or sawed concrete. (20) GS-29 specialties. Requires up to four years’ experience as determined on a case-by- case basis. The GS-29 classification is a sub-category of the general specialty classifications. It is a miscellaneous classification that is used to identify specific specialties on a case-by-case basis. [14.6.6.9 NMAC - Rp, 14.6.6.9 NMAC, 3/10/2022]
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-4 — (3) GS-4. Concrete, cement, walkways and driveways. Requires two years’ experience practical trade experience, one year of which must be foreman level. Mix, pour, place, and finish concrete,; includes all necessary preparatory work including excavation, form work, and placing of reinforcement materials; includes the installation on private property of curbs, gutters, sidewalks, and driveway culverts; may not perform this work in public rights-of-way unless subcontracted to a validly licensed GA licensee.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
Two years of practical trade experience, including one year at foreman level.
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 5
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-5 — (4) GS-5. Demolition. Requires two years’ experience. Demolish all or any portion of a buildings and structures authorized by the GB-98 classification, including demolition to portions of buildings and structures allowing additions and alterations to be completed to the remaining portions of the building or structure.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 7

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-7 — (5) GS-7. Drywall installation and texture. Requires two years’ experience. Installation of gypsum wallboard, and gypsum sheathing; includes taping, bedding and coating the surfaces of the wallboard and sheathing with gypsum joint systems, tape and drywall mud, or a combination of other materials to create a permanent surface or coating and of walls and ceilings; install steel or wood stud systems (non-structural) and channel iron work to provide a base for the application of drywall.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 8

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-8 — (6) GS-8. Earthmoving, excavating and ditching. Requires two years’ experience. Perform earthwork associated with or incidental to construction projects regulated by CID, using hand or power tools, machines that use air, fluids, or other material under pressure, or heavy equipment, in such a manner that cutting, filling, excavating, grading, trenching, backfilling, boring and any similar excavating activity can be executed; earthmoving, excavating and ditching activities applicable to the preparation and production of agriculture or maintenance of livestock on a farm or ranch are exempt from licensing requirements.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — GS 9

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
GS-9 — (7) GS-9. Elevators, escalators, and related machinery (non-electrical). Requires two years’ experience. Erect, install or repair elevators, escalators and related machinery, including sheave beams, sheaves, cable and wire rope, guides, cab, counterweights, doors, including sidewalk elevators, automatic and manual controls, signal systems and all other devices, apparatus, machinery and equipment (including fabrication on job site) essential to the safe and efficient installation and operation of electrical, hydraulic and manually operated elevators and escalators and conveyors designed specifically for the transportation of people.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MM 1

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-1 — (1) MM-1. Plumbing. Requires four years’ experience. Install, alter, repair, service, and maintain plumbing, plumbing fixtures, and piping, includes incidental concrete supports, and excavating, trenching and backfilling; includes hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; piping for fuel, oil and gasoline; piping and appurtenances for solar thermal energy systems; potable water irrigation sprinkler systems; swimming pools and spas; includes pneumatic or electric controls and control wiring not greater than 24 volts; septic tanks, manholes and sewer lines; does not include installation of natural gas fired appliances or natural gas piping; piping and agricultural sprinkler irrigation system installation and maintenance on farm or ranch property that moves water for livestock use or irrigation purposes from a privately owned well or pipeline, not connected to a public potable water supply are exempt from licensing requirements. When connected to a potable water source all connections must be downstream of an approved back flow prevention device. If a backflow prevention device is required it shall be permitted and installed by a properly certified journeyman employed by an appropriately licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MM 2

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-2 — (2) MM-2. Natural gas fitting. Requires four years’ experience. Install, alter, repair, service and maintain natural gas piping and fittings; install hot water heating systems not exceeding 30 p.s.i. or 400,000 b.t.u./hour input; steam and hot water boilers; may connect water to existing valved outlets; warm air heating systems including chimney connections, flues, refractories, burners, fittings valves, thermal insulation, accessories and incidental piping; warm air appliances and other listed gas appliances; incidental controls and control wiring, pneumatic control systems; includes all required excavating, trenching and backfilling. May not install LP Gas systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MM 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-3 — (3) MM-3. Heating, ventilation & air conditioning (HVAC). Requires four years’ experience. Install, alter, repair, service and maintain HVAC air handling and refrigeration equipment and piping, including fans, coils, condensing units, self-contained packaged air conditioning or heating units, evaporative cooling units, and ductwork and accessories including solar air heating and cooled mechanical air handling and 14.6.6 NMAC 8
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MM 4

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-4 — (4) MM-4. Heating, cooling and process piping. Requires four years’ experience. Install, alter, repair, service and maintain hydronic heating, cooling and process piping, piping and appurtenances for steam and hot water systems of any temperature or pressure range, chilled water systems, condensing water systems and other process piping systems; includes air handling equipment, pressure vessels, heat exchangers, boilers, refrigeration water chillers, cooling towers, fuel oil tanks and fuel oil piping; electric controls and control wiring not to exceed 24 volts; install high pressure and process piping solar thermal energy systems of any temperature or pressure range conveying gas or fluids other than potable water; water based fire protection sprinkler systems, dry chemical fire protection systems.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MM 98
Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MM-98 — (5) MM-98. Mechanical. Requires four years’ experience. Indicates licensure in individual classifications MM-1 through MM-4 and covers all work described in these classifications, as well as work described in the MS-3, MS-6, MS-12 and MS-14. C. Mechanical Specialty classifications:
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Trade Examination Slot
CID determines the required trade-specific examination(s), if any, for this approved classification. The official sources do not assign a currently identifiable named examination to this exact classification; this slot is an applicant condition under the contract. No umbrella examination is invented from its scope.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MS 12

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-12 — (3) MS-12. Fire protection sprinkler systems. Requires four years’ experience. Install alter, repair, service or maintain water-based fire protection systems required pressure or storage tanks, controls and control wiring up to 24 volts; excavate and backfill and install piping from structure to off-site water supply adjacent to fire protection system property; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a validly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MS 14

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-14 — (4) MS-14. Dry chemical fire protection. Requires four years’ experience. Install, alter, repair, or service or maintain gaseous or chemical based fire protection systems including carbon dioxide (CO), or clean agents; pressurized storage tanks, valves, temperature sensing devices, solenoid or safety shut-off devices and other incidental controls and control wiring up to 24 volts; bid or contract for structural alterations, electrical wiring, etc., incidental to the system installation, provided such work is performed by a properly licensed contractor.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
four years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MS 3

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-3 — (1) MS-3. Septic tanks & sewer. Requires two years’ experience. Install, alter, repair, service or maintain septic tanks and private sewage disposal systems, manholes and sewer lines, beginning at a connection to a public or private utility and ending at a point five feet beyond the outside wall of a building or structured; excavate, trench, backfill and grade as necessary; install or repair incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.
Temporary replacement qualifying party — MS 6

All of the following:

Attachment
Attach the certificate to a valid license; a never-attached certificate expires after twelve months and a detached certificate after two consecutive years.
Business Law Alternative
NMSA 1978 §60-13-16(C) permits an approved accredited business-and-law course completion certificate in lieu of the Business and Law exam. The exam remains a route leaf under this contract’s applicant-waiver rule.
Classification
MS-6 — (2) MS-6. Lawn sprinklers. Requires two years’ experience. Install, alter, repair, service or maintain potable water sprinkler systems; excavate, trench, backfill and grade as necessary; backflow prevention devices incidental plug-in type electrical control panels, controls and control wiring not to exceed 24 volts.
Conduct
Comply with child-support requirements; disqualifying convictions and CILA violations may prevent certification.
Education Credit
Accredited technical training counts at one-half year of experience for each training year, not exceeding half the required experience.
Examination Deadline
Temporary certificate is issued without an initial sitting, but the regular examinations must be passed within ninety days; subsequent required exams remain leaves.
Experience
two years’ experience
Minimum Age
At least eighteen years old.
Preapproval
Submit the complete application and notarized experience affidavits; obtain approval before examination and finish certification requirements within the six-month application/approval period.
Score Validity
Passing examination scores are valid for one year.
Temporary Eligibility
Regular qualifying-party employment ended without fault of the licensed contractor; employee is experienced in the same classification and has worked for that contractor for at least five years.
Work Recency
Required practical/trade experience must be within the ten years before application.

New Mexico Contractor Business and Law Examination

Examination outline
  • Licensing Requirements
  • Estimating and Bidding
  • Business Organization and Financial Management
  • Tax Laws
  • Labor Laws
  • Project Management and Lien Law
  • Contracts
  • Risk Management
  • Environmental and Safety
Examination sources

EE-98 Residential and Commercial Electrical

Examination outline
  • EE-98 Residential and Commercial Electrical Part 1
    • General Knowledge and Electrical Installation Requirements
    • Services, Feeders, and Branch Circuits
    • Overcurrent Protection
    • Grounding and Bonding
    • Conductors and Cables
    • Raceways and Boxes
    • Hazardous Locations, Special Occupancies, and Special Equipment
    • Lighting, Signs, and General-Use Equipment
    • Motors, Transformers, and Generators
    • New Mexico State Code
  • EE-98 Residential and Commercial Electrical Part 2
    • General Knowledge and Electrical Installation Requirements
    • Services, Feeders, and Branch Circuits
    • Overcurrent Protection
    • Grounding and Bonding
    • Conductors and Cables
    • Raceways and Boxes
    • Special Occupancies and Special Equipment, including Pools
    • Lighting and General-Use Equipment
    • New Mexico State Code
  • EE-98 Residential and Commercial Electrical Part 3 (Specialties)
    • Low Voltage, including Alarms
    • Electrical Signs and Outline Lighting
    • Cathodic Protection and Lightning Protection Systems
    • Telephone and Computer Systems
    • Sound and Communication Systems
Examination sources

EL-1 Electrical Distribution Systems, including Transmission Lines

Examination outline
  • General Knowledge and Electrical Installation Requirements
  • Electrical Supply/Substations
  • Transformers
  • Conductors
  • Poles and Structures
  • Grounding Methods
  • Overhead
  • Underground
  • Equipment and Safety
  • Equipment over 600 Volts
Examination sources

ER-1 Residential Electrical Wiring

Examination outline
  • General Knowledge and Electrical Installation Requirements
  • Services, Feeders, and Branch Circuits
  • Overcurrent Protection
  • Grounding and Bonding
  • Conductors and Cables
  • Raceways and Boxes
  • Special Occupancies and Special Equipment, including Pools
  • Lighting and General-Use Equipment
  • New Mexico State Code
  • Low Voltage
Examination sources

ES-1 Electrical Signs and Outline Lighting

Examination outline
  • General Knowledge and Theory
  • Wiring and Protection
  • Wiring Methods and Material
  • Equipment For General Use
  • Special Occupancies
  • Special Equipment
Examination sources

ES-10 Water Well Pump Installer

Examination outline
  • General Knowledge and Electrical Installation Requirements
  • Feeders and Branch Circuits
  • Overcurrent Protection
  • Grounding and Bonding
  • Conductors and Cables
  • Raceways and Boxes
  • Panelboards and Switchboards
  • Motors, Pumps, and Controls
  • Solar PV Systems
  • New Mexico Electrical Code
Examination sources

ES-10R Residential Water Well Pump Installer

Examination outline
  • General Knowledge and Electrical Installation Requirements
  • Feeders and Branch Circuits
  • Overcurrent Protection
  • Grounding and Bonding
  • Conductors and Cables
  • Raceways and Boxes
  • Panelboards and Switchboards
  • Motors, Pumps, and Controls
  • Solar PV Systems
  • New Mexico Electrical Code
Examination sources

ES-2 Cathodic Protection and Lightning Protection

Examination outline
  • General Electrical Knowledge
  • National Electrical Code
  • Lightning Protection
  • Cathodic Protection
Examination sources

ES-3 Low Voltage Special Systems (under 50 Volts)

Examination outline
  • Grounding and Bonding
  • Conductors
  • Electrical Power Conditioning
  • Electrical and Electronic Knowledge
  • General Low Voltage
  • Sound and Video Systems
  • Intrusion Detection and Alarms
  • Fire Detection and Alarms
  • Computer and Data Systems
  • CCTV Systems
  • Testing Equipment
  • CATV and MATV Systems
  • Applied Systems Design
Examination sources

ES-7 Telephone Communication Systems and Telephone Interconnect Systems

Examination outline
  • Grounding and Bonding
  • Conductors
  • Special Occupancies and Equipment
  • General Electrical Knowledge
  • Communication Systems
  • Outside Cabling
  • Cable Transmission and Reception
  • Poles
  • Inside Cabling
  • Network/Data
  • Switching
  • Telephones
  • Underground Cabling
Examination sources

GA-1 Streets, Roads, and Highways

Examination outline
  • Bituminous Surface Treatments and Pavement
  • Earthwork
  • Project Management (Planning, Estimating, Basis of Payment, One Call)
  • Heavy Equipment / Safety
  • Portland Cement Surface Treatments and Pavement
  • Erosion Control
  • Surveying
  • Miscellaneous (Curbs and Gutters, Concrete Wall Barrier, Fences, Signs)
Examination sources

GA-2 Maintenance and Repair

Examination outline
  • Bituminous Surface Treatments and Pavements
  • Project Management (Planning, Estimating, Basis of Payment)
  • Portland Cement Surface Treatments and Pavements
  • Heavy Equipment / Safety
Examination sources

GA-3 Curbs, Gutters, and Culverts

Examination outline
  • Earthwork / Surveying
  • Concrete
  • Curbs and Gutters
  • Culverts
  • Project Management (Planning, Estimating, Basis of Payment, One Call)
  • Heavy Equipment / Safety
Examination sources

GA-4 Striping

Examination outline
  • Pavement Markings
  • Planning
  • Equipment/Safety
  • Estimating/Basis of Payment
Examination sources

GA-5 Highway Signs and Guard Rails

Examination outline
  • Metal Barriers, Barricades, Traffic Control Devices
  • Highway Signs
  • Equipment Safety
  • Estimating/Basis of Payment
  • Planning
Examination sources

GB-2 Residential Building Contractor Part 1 Examination

Examination outline
  • Sitework, Footings, and Foundations
  • Concrete and Concrete Reinforcement
  • Masonry
  • Carpentry
  • Roofing
  • Associated Trades
  • General Code, Plan Reading, and Estimating
  • OSHA Safety
Examination sources

GB-98 General Building Contractor Examination

Examination outline
  • GB-2 Residential Building Contractor Part 1 Examination
    • Sitework, Footings, and Foundations
    • Concrete and Concrete Reinforcement
    • Masonry
    • Carpentry
    • Roofing
    • Associated Trades
    • General Code, Plan Reading, and Estimating
    • OSHA Safety
  • GB-98 General Building Contractor Part 2 Examination
    • Sitework, Footings, and Foundations
    • Concrete and Concrete Reinforcement
    • Masonry
    • Carpentry
    • Metals
    • Roofing
    • Associated Trades
    • General Code, Plan Reading, and Estimating
    • OSHA Safety
Examination sources

GF-CORE

Examination outline
  • Stormwater Management
  • OSHA Safety
  • Project Management
  • Surveying / Layout
  • New Mexico One-Call
  • Building Code / Inspections
Examination sources

GF-1 Airports

Examination outline
  • Sitework
  • Runways
  • FAA Regulations
  • Lighting
Examination sources

GF-2 Bridges

Examination outline
  • Sitework
  • Concrete
  • Metals
  • Asphalt Pavement
  • Rigging
  • Project Management
Examination sources

GF-3 Canals, Reservoirs, or Irrigation Systems

Examination outline
  • Irrigation
  • Concrete
  • Sitework
Examination sources

GF-4 Drainage or Flood Control Systems

Examination outline
  • Earthwork
  • Culverts and Pipe
  • Concrete
  • Project Management
Examination sources

GF-5 Recreation Areas

Examination outline
  • Sitework
  • Irrigation
  • Concrete
  • Project Management
Examination sources

GF-6 Railroad and Tunnel Construction

Examination outline
  • Railroad and tunnel construction
Examination sources

GF-7 Tanks and Towers

Examination outline
  • Miscellaneous Structures
  • Sitework / Excavation
  • Welding
  • Paving and Surfacing
  • Tanks
  • Towers
Examination sources

GF-8 Transmission Lines, Tanks, and Substations (Non- Electrical)

Examination outline
  • Tanks and Pipelines
  • Miscellaneous Structures / Corrosion Protection
  • Welding
  • Heavy Equipment / Safety
  • Paving and Surfacing
Examination sources

GF-9 Utility Lines

Examination outline
  • Pipe/Miscellaneous Structures
  • Earthwork
  • Surface Repair
  • Project Management
Examination sources

GS-13 Framing

Examination outline
  • Estimating and Plan Reading
  • Layout
  • Walls
  • Floors and Stairs
  • Roofs
  • OSHA Safety
Examination sources

GS-16 Masonry

Examination outline
  • Estimating and Plan Reading
  • Unit Masonry
  • Mortar and Grout
  • Accessories
  • Stone
  • Tools
  • Restoration and Cleaning
  • Safety
Examination sources

GS-21 Roofing

Examination outline
  • Estimating and Plan Reading
  • Surface Preparation and Planning
  • Steep and Low Slope Roofing
  • Roofing Components
  • Safety
Examination sources

GS-24 Structural Steel Erection

Examination outline
  • Materials
  • Rigging
  • Steel Erection
  • Attachment
  • Safety
Examination sources

GS-25 Swimming Pools

Examination outline
  • Plan Reading and Estimating
  • Sitework and Excavating
  • Forming and Reinforcing
  • Concrete
  • Shotcrete
  • Pool Equipment, Including ADA (No Plumbing or Electric)
  • Safety, Including CFR, Pool and Security Fencing
Examination sources

GS-30 Plastering, Stucco and Lathing

Examination outline
  • Estimating and Plan Reading
  • Surface Preparation
  • Materials
  • Installation
  • E.I.F.S.
  • Tools
  • Safety
Examination sources

GS-4 Concrete, Cement, Walkways, and Driveways

Examination outline
  • Estimating and Plan Reading
  • Layout and Excavation
  • Formwork
  • Reinforcing Steel
  • General Concrete
  • Safety
Examination sources

GS-7 Drywall Installation and Texture

Examination outline
  • Estimating and Plan Reading
  • Materials and Installation
  • Taping
  • Special Applications
  • Safety
Examination sources

GS-8 Earthmoving, Excavation, and Ditching

Examination outline
  • Estimating and Plan Reading
  • Equipment and Technique
  • Compaction
  • Soil Types
  • Specialty Work (Blasting, Shoring)
  • Safety
Examination sources

GS-9 Elevators, Escalators, Conveyors

Examination outline
  • Commercial Elevators
  • Residential Elevators
  • Escalators/Moving Walks
  • Dumbwaiters
  • Emergency Service
Examination sources

MM-1 Plumbing

Examination outline
  • Drainage Waste and Vents
  • Water Supply Systems
  • Backflow Prevention
  • Storm Drainage Systems
  • Plumbing Fixtures incl Water Heaters/Accessibility
  • General Knowledge and General Regulations
  • Interceptors and Traps
  • Isometric Analysis
  • Septic and Sewer
Examination sources

MM-2 Natural Gas Fitting

Examination outline
  • General Knowledge and Principles
  • Piping
  • Gas Sizing
  • Safety and Testing
  • Appliances
  • Combustion Air
  • Chimneys, Flues, and Vents
  • Heating Systems
Examination sources

MM-3 Heat, Vent and Air Conditioning

Examination outline
  • Motors, Controls, and Low Voltage Wiring
  • Piping
  • Heating and Cooling General Knowledge
  • Heating and Cooling Equipment and Components
  • Refrigerants and Refrigeration
  • Duct Work, Ventilation, and Exhaust
Examination sources

MM-4 Heat, Cooling, and Process Pipe

Examination outline
  • General Knowledge
  • Steam and Hot Water Boiler Systems
  • Process Piping and Systems
  • Fire Suppression Systems
  • Controls and Components
  • Combustion Air and Venting
Examination sources

MS-12 Fire Protection Systems

Examination outline
  • Backflow Prevention
  • Hydraulic Calculations and Design
  • Residential Systems
  • Fire pumps and Standpipes
  • Sprinkler Systems
  • Water Supply, Storage, and Distribution
  • General and Code Knowledge
  • Materials and Methods
  • Testing and Inspections (NFPA 25)
Examination sources

MS-14 Dry Chemical Fire Protection

Examination outline
  • Clean Agents and Alternative Systems
  • Foam Systems
  • Wet Chemical Systems
  • Dry Chemical Systems
  • Carbon Dioxide Systems
  • Portable Fire Extinguishers
  • Commercial Kitchen Equipment
Examination sources

MS-3 Cesspools, Septic Tanks and Sewers

Examination outline
  • General Knowledge
  • Installation and Materials
  • Septic Tanks
  • Disposal Absorption Fields
  • Building Sewers
  • Alternative Disposal
Examination sources

MS-6 Lawn Sprinklers

Examination outline
  • General Knowledge
  • Design
  • Materials
  • Controls and Wiring
  • Excavation
  • Pumps
  • Water Supply
  • Sprinkler Heads
Examination sources

EV-98 Elevators, Escalators, Conveyors

Examination outline
  • Commercial Elevators
  • Escalators/Moving Walks
  • Dumbwaiters
  • Emergency Service
Examination sources